Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 161

The DOI matches its Crossref record.

Effects of collagenase and elastase on the mechanical properties of lung tissue strips

Yuan, Huichin, Kononov, Stefanida, Cavalcante, Francisco S. A., Lutchen, Kenneth R., Ingenito, Edward P., Suki, Béla·2000·Journal of Applied Physiology

Abstract

The dynamic stiffness (H), damping coefficient (G), and harmonic distortion ( k d) characterizing tissue nonlinearity of lung parenchymal strips from guinea pigs were assessed before and after treatment with elastase or collagenase between 0.1 and 3.74 Hz. After digestion, data were obtained both at the same mean length and at the same mean force of the strip as before digestion. At the same mean length, G and H decreased by ∼33% after elastase and by ∼47% after collagenase treatment. At the same mean force, G and H increased by ∼7% after elastase and by ∼25% after collagenase treatment. The k d increased more after collagenase (40%) than after elastase (20%) treatment. These findings suggest that, after digestion, the fraction of intact fibers decreases, which, at the same mean length, leads to a decrease in moduli. At the same mean force, collagen fibers operate at a higher portion of their stress-strain curve, which results in an increase in moduli. Also, G and H were coupled so that hysteresivity (G/H) did not change after treatments. However, k d was decoupled from elasticity and was sensitive to stretching of collagen, which may be of value in detecting structural alterations in the connective tissue of the lung.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.2000.89.1.3

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 161

Metadata

Authors
Yuan, H., Kononov, S., Cavalcante, F. S. A., Lutchen, K. R., Ingenito, E. P., & Suki, B.
Venue
Journal of Applied Physiology
Published
2000-07-01
Volume
89
Issue
1
Pages
3-14
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2167080502
Cited by
161
References
0
FWCI
3.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of collagenase and elastase on the mechanical properties of lung tissue strips. https://app.cochat.ai/papers/10.1152/jappl.2000.89.1.3
The paper
Yuan, H., Kononov, S., Cavalcante, F. S. A., Lutchen, K. R., Ingenito, E. P., & Suki, B. (2000). Effects of collagenase and elastase on the mechanical properties of lung tissue strips. Journal of Applied Physiology. https://doi.org/10.1152/jappl.2000.89.1.3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.