The DOI matches its Crossref record.
Influence of static stretching on viscoelastic properties of human tendon structures in vivo
Abstract
The purpose of this study was to investigate the influences of static stretching on the viscoelastic properties of human tendon structures in vivo. Seven male subjects performed static stretching in which the ankle was passively flexed to 35° of dorsiflexion and remained stationary for 10 min. Before and after the stretching, the elongation of the tendon and aponeurosis of medial gastrocnemius muscle (MG) was directly measured by ultrasonography while the subjects performed ramp isometric plantar flexion up to the maximum voluntary contraction (MVC), followed by a ramp relaxation. The relationship between the estimated muscle force (Fm) of MG and tendon elongation ( L) during the ascending phase was fitted to a linear regression, the slope of which was defined as stiffness of the tendon structures. The percentage of the area within the Fm- L loop to the area beneath the curve during the ascending phase was calculated as an index representing hysteresis. Stretching produced no significant change in MVC but significantly decreased stiffness and hysteresis from 22.9 ± 5.8 to 20.6 ± 4.6 N/mm and from 20.6 ± 8.8 to 13.5 ± 7.6%, respectively. The present results suggest that stretching decreased the viscosity of tendon structures but increased the elasticity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A stretchable and biodegradable strain and pressure sensor for orthopaedic application
Boutry, C. M., Kaizawa, Y., Schroeder, B. C., Chortos, A., Legrand, A., Wang, Z., Chang, J., Fox, P., & Bao, Z. (2018) · Nature Electronics · doi:10.1038/s41928-018-0071-7 · Cited by 667
Effect of strength training on human patella tendon mechanical properties of older individuals
Reeves, N. D., Maganaris, C. N., & Narici, M. V. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2002.035576 · Cited by 484
Effect of strength training on human patella tendon mechanical properties of older individuals
Reeves, N. D., Maganaris, C. N., & Narici, M. V. (2003) · The Journal of Physiology · doi:10.1111/j..2003.t01-1-00971.x · Cited by 484
Morse, C. I., Degens, H., Seynnes, O. R., Maganaris, C. N., & Jones, D. A. (2008) · The Journal of Physiology · doi:10.1113/jphysiol.2007.140434 · Cited by 421
Collagen Structure of Tendon Relates to Function
Franchi, M., Trirè, A., Quaranta, M., Orsini, E., & Ottani, V. (2007) · The Scientific World JOURNAL · doi:10.1100/tsw.2007.92 · Cited by 349
Metadata
- Authors
- Kubo, K., Kanehisa, H., Kawakami, Y., & Fukunaga, T.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2001-02-01
- Volume
- 90
- Issue
- 2
- Pages
- 520-527
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2104777836
- Cited by
- 397
- References
- 0
- FWCI
- 10.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of static stretching on viscoelastic properties of human tendon structures in vivo. https://app.cochat.ai/papers/10.1152/jappl.2001.90.2.520
- The paper
- Kubo, K., Kanehisa, H., Kawakami, Y., & Fukunaga, T. (2001). Influence of static stretching on viscoelastic properties of human tendon structures in vivo. Journal of Applied Physiology. https://doi.org/10.1152/jappl.2001.90.2.520
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.