Cited by 43Cardiovascular Syncope and Autonomic DisordersHeart Rate Variability and Autonomic ControlCardiovascular and exercise physiology

Reflex vascular defects in the orthostatic tachycardia syndrome of adolescents

Stewart, Julian M., Weldon, Amy·2001·Journal of Applied Physiology

Abstract

Dependent pooling occurs in postural orthostatic tachycardia syndrome (POTS) related to defective vasoconstriction. Increased venous pressure (Pv) >20 mmHg occurs in some patients (high Pv) but not others (normal Pv). We compared 22 patients, aged 12-18 yr, with 13 normal controls. Continuous blood pressure and strain-gauge plethysmography were used to measure supine forearm and calf blood flow, resistance, venous compliance, and microvascular filtration, and blood flow and swelling during 70 degrees head-up tilt. Supine, high Pv had normal resistance in arms (26 +/- 2 mmHg x ml(-1) x 100 ml x min) and legs (34 +/- 3 mmHg x ml(-1) x 100 ml x min) but low leg blood flow (1.5 +/- 0.4 ml x 100 ml(-1) x min(-1)). Supine leg Pv (30 +/- 2 vs. 13 +/- 1 mmHg in control) exceeded the threshold for edema (isovolumetric pressure = 19 +/- 3 mmHg). Supine, normal Pv had high blood flow in arms (4.1 +/- 0.2 vs. 3.5 +/- 0.2 ml x 100 ml(-1) x min(-1) in control) and legs (3.8 +/- 0.4 vs. 2.7 +/- 0.3 ml x 100 ml(-1) x min(-1) in control) with low resistance. With tilt, calf blood flow increased steadily in POTS with high Pv and transiently increased in normal Pv. Calf volume increased in all POTS patients. Arm blood flow increased in normal Pv only with forearm maintained at heart level. These data suggest that there are (at least) two subgroups of POTS characterized by high Pv and low flow or normal Pv and high flow. These may correspond to abnormalities in local or baroreceptor-mediated vasoconstriction, respectively.

Integrity signals

Registry

Crossref · 10.1152/jappl.2001.90.6.2025

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Pediatric patients with POTS had excessive pooling of blood in the lower extremities, primarily due to arteriolar dysregulation rather than inappropriately increased venous capacitance.

    “Stewart et al. (14-17) noted that pediatric patients with POTS had excessive pooling of blood in the lower extremities, primarily due to arteriolar dysregulation rather than inappropriately increased venous capacitance.”

The citation lists haven’t been fetched yet

References 29 · Cited by 43

Authors
Stewart, J. M., & Weldon, A.
Affiliations
  • New York Medical College (US)
  • Departments of Pediatrics and
Venue
Journal of Applied Physiology
Published
2001-06-01
Volume
90
Issue
6
Pages
2025-2032
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2284161010
Cited by
43
References
29
Citations by year
2025: 4 · 2021: 2 · 2020: 2 · 2019: 1 · 2018: 4 · 2016: 2 · 2014: 2 · 2013: 1
FWCI
4.62
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Applied Physiology (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (5r03ai045954-02)
  • National Institute of Allergy and Infectious Diseases (1RO3-AI-45954)
Topics
  • Health Sciences › Medicine › Surgery › Cardiovascular Syncope and Autonomic Disorders
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
Keywords
postural orthostatic tachycardia syndrome, venous pressure, venous pooling, vasoconstriction, calf blood flow, forearm blood flow, venous compliance, edema, head-up tilt, adolescents, baroreflex, subgroup classification
MeSH terms
Adolescent, Child, Extremities, Female, Hemodynamics, Humans, Male, Posture, Reflex, Regional Blood Flow, Syndrome, Tachycardia, Vascular Resistance, Vasodilation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review