Continuous measurement of breathlessness during exercise: validity, reliability, and responsiveness
The DOI matches its Crossref record.
Abstract
A continuous method for recording changes in breathlessness (dyspnea) during exercise is introduced and compared with the traditional discrete method. In study 1, a category-rating scale was presented on a computer screen, and 14 healthy, young female subjects exercised on a cycle ergometer until exhaustion. Two approaches were used to obtain ratings of breathlessness: a discrete method, in which subjects gave single judgments every minute, and a continuous method, in which subjects throughout exercise moved the mouse so that a bar on the screen extended to the desired location along the scale. Psychophysical results relating measures of breathlessness and the variables of work, oxygen consumption, and minute ventilation were statistically indistinguishable with the two methods, and both methods were highly reliable across test sessions. In study 2, both measurement methods were employed, and the subjects were 14 healthy, young males. In each of two sessions (discrete or continuous method), subjects first rated their breathlessness during an incremental test in which the workload was increased over time and levels of work, and minute ventilation were recorded. Subjects then exercised for 10 min at 60% of the maximal oxygen consumption achieved during the incremental test. At two points during steady-state exercise, a respiratory load was introduced that lasted for 1 min. It was possible to determine the responsiveness of subjects to onset and offset of the respiratory load for the continuous method but not for the discrete method. In study 3, patients with chronic obstuctive pulmonary disease employed both methods, and it was found that the continuous method was better at determining whether subjects showed a significant positive slope of the regression line between breathlessness ratings and physiological variables.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Outcomes for COPD pharmacological trials: from lung function to biomarkers
Cazzola, M., MacNee, W., Martinez, F. J., Rabe, K. F., Franciosi, L. G., Barnes, P. J., Brusasco, V., Burge, P. S., Calverley, P. M. A., Celli, B. R., et al. (2008) · European Respiratory Journal · doi:10.1183/09031936.00099306 · Cited by 858
Self-citationRelevance of assessing quadriceps endurance in patients with COPD
Coronell, C., Orozco‐Levi, M., Méndez, R., Ramírez‐Sarmiento, A., Gáldiz, J. B., & Gea, J. (2004) · European Respiratory Journal · doi:10.1183/09031936.04.00079603 · Cited by 195
Boudreau, M., Lavoie, K. L., Cartier, A., Trutshnigg, B., Morizio, A., Lemière, C., & Bacon, S. L. (2015) · Respiratory Medicine · doi:10.1016/j.rmed.2015.09.002 · Cited by 18
Metadata
- Authors
- Mahler, D. A., Mejia-Alfaro, R., Ward, J., & Baird, J. C.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2001-06-01
- Volume
- 90
- Issue
- 6
- Pages
- 2188-2196
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1774976159
- Cited by
- 51
- References
- 0
- FWCI
- 4.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous measurement of breathlessness during exercise: validity, reliability, and responsiveness. https://app.cochat.ai/papers/10.1152/jappl.2001.90.6.2188
- The paper
- Mahler, D. A., Mejia-Alfaro, R., Ward, J., & Baird, J. C. (2001). Continuous measurement of breathlessness during exercise: validity, reliability, and responsiveness. Journal of Applied Physiology. https://doi.org/10.1152/jappl.2001.90.6.2188
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.