The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Comparison of OPS imaging and conventional capillary microscopy to study the human microcirculation
Abstract
Orthogonal polarization spectral (OPS) imaging is a new clinical technique for observation of the microcirculation of organ surfaces. For validation purposes, we compared OPS images of the nailfold skin with those obtained from conventional capillary microscopy at rest and during venous occlusion in 10 male volunteers. These images were computer analyzed to provide red blood cell velocity and capillary diameters of the same nailfold capillaries at rest and during venous occlusion. Results showed that OPS images provided similar values for red blood cell velocity and capillary diameter as those obtained from capillary microscopy images. OPS imaging, however, provided significantly better image quality, as shown by comparison of image contrast between OPS imaging and capillary microscopy. This made image analysis better and easier to perform. It is anticipated, therefore, that OPS imaging will become a new and powerful technique in the study of the human microcirculation in vivo because it can be used on human internal organs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Microvascular Blood Flow Is Altered in Patients with Sepsis
De Backer, D., Creteur, J., Preiser, J.-C., Dubois, M.-J., & Vincent, J.-L. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200109-016oc · Cited by 1,473
Sakr, Y., Dubois, M.-J., De Backer, D., Creteur, J., & Vincent, J.-L. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000138558.16257.3f · Cited by 1,266
How to evaluate the microcirculation: report of a round table conference
De Backer, D., Hollenberg, S., Boerma, C., Goedhart, P., Büchele, G., Ospina-Tascon, G., Dobbe, I., & Ince, C. (2007) · Critical Care · doi:10.1186/cc6118 · Cited by 830
Self-citationTrzeciak, S., Dellinger, R. P., Parrillo, J. E., Guglielmi, M., Bajaj, J., Abate, N. L., Arnold, R. C., Colilla, S., Zanotti, S., & Hollenberg, S. M. (2007) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2006.08.021 · Cited by 609
Nitroglycerin in septic shock after intravascular volume resuscitation
Spronk, P. E., Ince, C., Gardien, M. J., Mathura, K. R., Straaten, H. M. O.-V., & Zandstra, D. F. (2002) · The Lancet · doi:10.1016/s0140-6736(02)11393-6 · Cited by 541
Self-citation
Metadata
- Authors
- Mathura, K. R., Vollebregt, K. C., Boer, K., De Graaff, J. C., Ubbink, D. T., & Ince, C.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2001-07-01
- Volume
- 91
- Issue
- 1
- Pages
- 74-78
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2161938631
- Cited by
- 195
- References
- 1
- FWCI
- 8.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of OPS imaging and conventional capillary microscopy to study the human microcirculation. https://app.cochat.ai/papers/10.1152/jappl.2001.91.1.74
- The paper
- Mathura, K. R., Vollebregt, K. C., Boer, K., De Graaff, J. C., Ubbink, D. T., & Ince, C. (2001). Comparison of OPS imaging and conventional capillary microscopy to study the human microcirculation. Journal of Applied Physiology. https://doi.org/10.1152/jappl.2001.91.1.74
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.