Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 170

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Comparison of lung protection strategies using conventional and high-frequency oscillatory ventilation

Imai, Yumiko, Nakagawa, Satoshi, Ito, Yushi, Kawano, Toshio, Slutsky, Arthur S., Miyasaka, Katsuyuki · 2001 · Journal of Applied Physiology

Abstract

This study compared pathophysiological and biochemical indexes of acute lung injury in a saline-lavaged rabbit model with different ventilatory strategies: a control group consisting of moderate tidal volume (Vt) (10–12 ml/kg) and low positive end-expiratory pressure (PEEP) (4–5 cmH 2 O); and three protective groups: 1) low Vt (5–6 ml/kg) high PEEP, 2–3 cmH 2 O greater than the lower inflection point; 2) low Vt (5–6 ml/kg), high PEEP (8–10 cmH 2 O); and 3) high-frequency oscillatory ventilation (HFOV). The strategy using PEEP > inflection point resulted in hypotension and barotrauma. HFOV attenuated the decrease in pulmonary compliance, the lung inflammation assessed by polymorphonuclear leukocyte infiltration and tumor necrosis factor-α concentration in the alveolar space, and pathological changes of the small airways and alveoli. Conventional mechanical ventilation using lung protection strategies (low Vt high PEEP) only attenuated the decrease in oxygenation and pulmonary compliance. Therefore, HFOV may be a preferable option as a lung protection strategy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.2001.91.4.1836

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 170

Metadata

Authors
Imai, Y., Nakagawa, S., Ito, Y., Kawano, T., Slutsky, A. S., & Miyasaka, K.
Venue
Journal of Applied Physiology
Published
2001-10-01
Volume
91
Issue
4
Pages
1836-1844
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2156668993
Cited by
170
References
2
FWCI
6.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of lung protection strategies using conventional and high-frequency oscillatory ventilation. https://app.cochat.ai/papers/10.1152/jappl.2001.91.4.1836
The paper
Imai, Y., Nakagawa, S., Ito, Y., Kawano, T., Slutsky, A. S., & Miyasaka, K. (2001). Comparison of lung protection strategies using conventional and high-frequency oscillatory ventilation. Journal of Applied Physiology. https://doi.org/10.1152/jappl.2001.91.4.1836

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.