CoChat

Time course of regional vascular adaptations to low load resistance training with blood flow restriction

Open access
Hunt, Julie E. A., Galea, Dermot, Tufft, Graham, Bunce, Danny, Ferguson, Richard A. · 2013 · Journal of Applied Physiology
Cited by 95

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Distortion to hemodynamic and ischemic stimuli during blood flow restriction (BFR) exercise may influence regional vascular adaptation. We examined changes at the conduit, resistance, and capillary level in response to low load resistance exercise with BFR. Eleven males (22 ± 3 yr, 178 ± 4 cm, 78 ± 9 kg) completed 6 wk (3 days/wk) unilateral plantar flexion training with BFR at 30% 1 repetition maximum (1-RM). The contralateral leg acted as a nonexercised control (CON). Popliteal artery function [flow-mediated dilation, FMD%] and structure [maximal diameter] and resistance vessel structure [peak reactive hyperemia] were assessed using Doppler ultrasound before and at 2-wk intervals. Calf filtration capacity was assessed using venous occlusion plethysmography before and after training. BFR training elicited an early increase in peak reactive hyperemia (1,400 ± 278 vs. 1,716 ± 362 ml/min at 0 vs. 2 wk; t-test: P = 0.047), a transient improvement in popliteal FMD% (5.0 ± 2.1, 7.6 ± 2.9, 6.6 ± 2.1, 5.7 ± 1.6% at 0, 2, 4 and 6 wk, respectively; ANOVA: P = 0.002), and an increase in maximum diameter (6.06 ± 0.44 vs. 6.26 ± 0.39 mm at 0 vs. 6 wk; Bonferroni t-test: P = 0.048). Capillary filtration increased after 6 wk BFR training ( P = 0.043). No changes in the CON leg were observed. Adaptation occurred at all levels of the vascular tree in response to low load resistance exercise with BFR. Enhanced peak reactive hyperemia and transient improvement in popliteal artery function occurred before changes in artery structural capacity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00040.2013

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 95

Metadata

Authors
Hunt, J. E. A., Galea, D., Tufft, G., Bunce, D., & Ferguson, R. A.
Venue
Journal of Applied Physiology
Published
2013-08-01
Volume
115
Issue
3
Pages
403-411
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W1987484595
Cited by
95
References
3
FWCI
8.74
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Time course of regional vascular adaptations to low load resistance training with blood flow restriction. https://app.cochat.ai/papers/10.1152/japplphysiol.00040.2013
The paper
Hunt, J. E. A., Galea, D., Tufft, G., Bunce, D., & Ferguson, R. A. (2013). Time course of regional vascular adaptations to low load resistance training with blood flow restriction. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00040.2013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.