Assessment of brachial artery blood flow across the cardiac cycle: retrograde flows during cycle ergometry
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We describe a novel software system that utilizes automated algorithms to perform edge detection and wall tracking of high-resolution B-mode arterial ultrasound images, combined with synchronized Doppler waveform envelope analysis, to calculate conduit arterial blood flow (BF) across the cardiac cycle. Furthermore, we describe changes in brachial arterial BF to the resting forearm during incremental cycle ergometry in eight subjects. During exercise, peak BF during the cardiac cycle increased at each workload ( P < 0.001), because of increased velocity in the presence of unaltered cross-sectional area. In contrast, mean BF calculated across each cardiac cycle decreased at lower workloads before increasing at 100 and 160 W ( P< 0.001). Differences in the pattern of peak and mean cardiac cycle flows were due to the influence of retrograde diastolic flow, which had a larger impact on mean flows at lower workloads. In conclusion, BF can be measured with high temporal resolution across the cardiac cycle in humans. Resting brachial arterial flow, including retrograde flow, increases during lower limb exercise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Joyner, M. J., Dietz, N. M., & Shepherd, J. T. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.6.2431 · Cited by 177
Cited by
Effect of exercise training on endothelium‐derived nitric oxide function in humans
Green, D. J., Maiorana, A., O'Driscoll, G., & Taylor, R. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2004.068197 · Cited by 1,040
Self-citationVascular Adaptation to Exercise in Humans: Role of Hemodynamic Stimuli
Green, D. J., Hopman, M. T. E., Padilla, J., Laughlin, M. H., & Thijssen, D. H. J. (2017) · Physiological Reviews · doi:10.1152/physrev.00014.2016 · Cited by 821
Self-citationImportance of Measuring the Time Course of Flow-Mediated Dilatation in Humans
Black, M. A., Cable, N. T., Thijssen, D. H. J., & Green, D. J. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.101014 · Cited by 393
Self-citationImpact of Shear Rate Modulation on Vascular Function in Humans
Tinken, T. M., Thijssen, D. H. J., Hopkins, N., Black, M. A., Dawson, E. A., Minson, C. T., Newcomer, S. C., Laughlin, M. H., Cable, N. T., & Green, D. J. (2009) · Hypertension · doi:10.1161/hypertensionaha.109.134361 · Cited by 333
Self-citationRetrograde Flow and Shear Rate Acutely Impair Endothelial Function in Humans
Thijssen, D. H. J., Dawson, E. A., Tinken, T. M., Cable, N. T., & Green, D. J. (2009) · Hypertension · doi:10.1161/hypertensionaha.109.131508 · Cited by 311
Self-citation
Metadata
- Authors
- Green, D., Cheetham, C., Reed, C., Dembo, L., & O'Driscoll, G.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2002-07-01
- Volume
- 93
- Issue
- 1
- Pages
- 361-368
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2100646418
- Cited by
- 131
- References
- 1
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of brachial artery blood flow across the cardiac cycle: retrograde flows during cycle ergometry. https://app.cochat.ai/papers/10.1152/japplphysiol.00051.2002
- The paper
- Green, D., Cheetham, C., Reed, C., Dembo, L., & O'Driscoll, G. (2002). Assessment of brachial artery blood flow across the cardiac cycle: retrograde flows during cycle ergometry. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00051.2002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.