The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Improving assessment of daily energy expenditure by identifying types of physical activity with a single accelerometer
Open accessAbstract
Accelerometers are often used to quantify the acceleration of the body in arbitrary units (counts) to measure physical activity (PA) and to estimate energy expenditure. The present study investigated whether the identification of types of PA with one accelerometer could improve the estimation of energy expenditure compared with activity counts. Total energy expenditure (TEE) of 15 subjects was measured with the use of double-labeled water. The physical activity level (PAL) was derived by dividing TEE by sleeping metabolic rate. Simultaneously, PA was measured with one accelerometer. Accelerometer output was processed to calculate activity counts per day (AC D) and to determine the daily duration of six types of common activities identified with a classification tree model. A daily metabolic value (MET D) was calculated as mean of the MET compendium value of each activity type weighed by the daily duration. TEE was predicted by AC D and body weight and by AC D and fat-free mass, with a standard error of estimate (SEE) of 1.47 MJ/day, and 1.2 MJ/day, respectively. The replacement in these models of AC D with MET D increased the explained variation in TEE by 9%, decreasing SEE by 0.14 MJ/day and 0.18 MJ/day, respectively. The correlation between PAL and MET D ( R 2 = 51%) was higher than that between PAL and AC D ( R 2 = 46%). We conclude that identification of activity types combined with MET intensity values improves the assessment of energy expenditure compared with activity counts. Future studies could develop models to objectively assess activity type and intensity to further increase accuracy of the energy expenditure estimation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Self-citationPhysical activity as determinant of daily energy expenditure
Westerterp, K. R. (2008) · Physiology & Behavior · doi:10.1016/j.physbeh.2008.01.021 · Cited by 103
Self-citation
Cited by
Medicine & science in sports & exercise
(1994) · Journal of the American Dietetic Association · doi:10.1016/0002-8223(94)92575-5 · Cited by 1,303
Best Practices for Using Physical Activity Monitors in Population-Based Research
MATTHEWS, C. E., HAGSTRÖMER, M., POBER, D. M., & BOWLES, H. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399e5b · Cited by 703
Assessment of Physical Activity and Energy Expenditure: An Overview of Objective Measures
Hills, A. P., Mokhtar, N., & Byrne, N. M. (2014) · Frontiers in Nutrition · doi:10.3389/fnut.2014.00005 · Cited by 575
Ohkawara, K., Oshima, Y., Hikihara, Y., Ishikawa-Takata, K., Tabata, I., & Tanaka, S. (2011) · British Journal of Nutrition · doi:10.1017/s0007114510005441 · Cited by 458
Optimal Placement of Accelerometers for the Detection of Everyday Activities
Cleland, I., Kikhia, B., Nugent, C., Boytsov, A., Hallberg, J., Synnes, K., McClean, S., & Finlay, D. (2013) · Sensors · doi:10.3390/s130709183 · Cited by 401
Metadata
- Authors
- Bonomi, A. G., Plasqui, G., Goris, A. H. C., & Westerterp, K. R.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2009-09
- Volume
- 107
- Issue
- 3
- Pages
- 655-661
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2065377245
- Cited by
- 196
- References
- 3
- FWCI
- 9.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.