Cited by 37Obstructive Sleep Apnea ResearchNeuroscience of respiration and sleepRespiratory Support and Mechanisms

Daytime loop gain is elevated in obstructive sleep apnea but not reduced by CPAP treatment

Open access
Deacon-Diaz, Naomi Louise, Sands, Scott A., McEvoy, R. Doug, Catcheside, Peter G.·2018·Journal of Applied Physiology

Abstract

Reduced ventilatory control stability (elevated loop gain) is a key nonanatomical, pathological trait contributing to obstructive sleep apnea (OSA), yet the mechanisms responsible remain unclear. We sought to identify the key factors contributing to elevated loop gain in OSA (controller vs. plant contributions) and to examine whether abnormalities in these factors persist after OSA treatment. In 15 males (8 OSA, 7 height, weight- and age -matched controls), we measured loop gain, controller gain, and plant gain using a pseudorandom binary CO 2 stimulation method during wakefulness. Factors potentially influencing plant gain were also assessed (supine lung volume via helium dilution and spirometry). Measures were repeated 2 and 6 wk after initiating continuous positive airway pressure treatment. Loop gain (LG) was higher in OSA versus controls (LG at 1 cycle/min 0.28 ± 0.04 vs. 0.16 ± 0.04, P = 0.046, respectively), and the controller exhibited a greater peak response to CO 2 and faster roll-off in OSA. OSA patients also exhibited reduced forced expiratory volume in the first second and forced vital capacity compared with controls (92.2 ± 1.7 vs. 102.9 ± 3.5% predicted, P = 0.021; 93.4 ± 3.1 vs. 106.6 ± 3.6% predicted, P = 0.015, respectively). There was no effect of treatment on any variable. These findings confirm loop gain is higher in untreated OSA patients than in matched controls; however, this was not affected by treatment. NEW & NOTEWORTHY Elevated loop gain contributes to obstructive sleep apnea (OSA) pathophysiology. However, whether loop gain is inherently elevated in OSA or induced by OSA itself, whether it is elevated due to increased chemoreflex sensitivity or obesity-dependent reduced lung volume, and whether it is treatment reversible, are all currently uncertain. This study found loop gain was elevated in OSA versus age-, sex-, height-, and weight-matched controls. However, this was not altered by 6-wk continuous positive airway pressure treatment.

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00175.2018

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Breathing dysfunction has been correlated with OSA pathophysiology, specifically with reduced ventilatory control stability and an elevated loop gain, a non-anatomical contributor trait to OSA.

    “It has been correlated with OSA pathophysiology, specifically with reduced ventilatory control stability, and an elevated loop gain, 105 a non-anatomical contributor trait to OSA. 106”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Deacon-Diaz, N. L., Sands, S. A., McEvoy, R. D., & Catcheside, P. G.
Affiliations
  • Discipline of Physiology, School of Medical Sciences, University of Adelaide, Adelaide, South Australia, Australia
  • Brigham and Women's Hospital (US)
  • Flinders University (AU)
Venue
Journal of Applied Physiology
Published
2018-11-01
Volume
125
Issue
5
Pages
1490-1497
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2889262372
Cited by
37
References
4
Citations by year
2026: 5 · 2025: 1 · 2024: 5 · 2023: 4 · 2022: 2 · 2021: 5 · 2020: 7 · 2019: 7 · 2018: 1
FWCI
3.44
Type
journal article
Language
en
Open access
Locations
  • Journal of Applied Physiology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
Funders
  • American Heart Association (AHA) (15SDG25890059)
  • Department of Health, Australian Government | National Health and Medical Research Council (NHMRC) (1053201)
  • R.G.Menzies Foundation (R01HL128658)
  • American Thoracic Society (ATS) (2R01HL102321)
  • National Institute of Health (P01HL10050580)
  • Australian Research Council Future Fellowship (FT120100510)
Topics
  • Health Sciences › Medicine › Physiology › Obstructive Sleep Apnea Research
  • Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Neuroscience of respiration and sleep
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
Keywords
obstructive sleep apnea, loop gain, control gain, continuous positive airway pressure, CO2 stimulation, chemoreflex sensitivity, lung volume, lung function
MeSH terms
Adult, Humans, Lung, Male, Middle Aged, Respiration, Respiratory Function Tests, Case-Control Studies, Sleep Apnea, Obstructive, Feedback, Physiological, Continuous Positive Airway Pressure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review