Arterial baroreflex control of heart rate during exercise in postural tachycardia syndrome
Abstract
Patients with postural tachycardia syndrome (POTS) have excessive tachycardia without hypotension during orthostasis as well as exercise. We tested the hypothesis that excessive tachycardia during exercise in POTS is not related to abnormal baroreflex control of heart rate (HR). Patients ( n = 13) and healthy controls ( n = 10) performed graded cycle exercise at 25, 50, and 75 W in both supine and upright positions while arterial pressure (arterial catheter) and HR (ECG) were measured. Baroreflex sensitivity of HR was assessed by bolus intravenous infusion of phenylephrine at each workload. In both positions, HR was higher in the patients than the controls during exercise. Supine baroreflex sensitivity (HR/systolic pressure) in POTS patients was −1.3 ± 0.1 beats·min−1·mmHg−1 at rest and decreased to −0.6 ± 0.1 beats·min−1·mmHg−1 during 75-W exercise, neither significantly different from the controls ( P > 0.6). In the upright position, baroreflex sensitivity in POTS patients at rest (−1.4 ± 0.1 beats·min−1·mmHg−1) was higher than the controls (−1.0 ± 0.1 beats·min−1·mmHg−1) ( P < 0.05), and it decreased to −0.1 ± 0.04 beats·min−1·mmHg−1 during 75-W exercise, lower than the controls (−0.3 ± 0.09 beats·min−1·mmHg−1) ( P < 0.05). The reduced arterial baroreflex sensitivity of HR during upright exercise was accompanied by greater fluctuations in systolic and pulse pressure in the patients than in the controls with 56 and 90% higher coefficient of variations, respectively ( P < 0.01). However, when baroreflex control of HR was corrected for differences in HR, it was similar between the patients and controls during upright exercise. These results suggest that the tachycardia during exercise in POTS was not due to abnormal baroreflex control of HR.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Excessive tachycardia in POTS occurs during exercise as well as standing, and patients experience significant exercise intolerance.
“Excessive tachycardia in POTS occurs during exercise as well as during standing [60;61], and patients experience significant exercise intolerance [9;19].”
From Postural tachycardia syndrome: beyond orthostatic intolerance (2015) · cites this paper as [60]
The citation lists haven’t been fetched yet
References 36 · Cited by 28
- Authors
- Masuki, S., Eisenach, J. H., Schrage, W. G., Dietz, N. M., Johnson, C. P., Wilkins, B. W., Dierkhising, R. A., Sandroni, P., Low, P. A., & Joyner, M. J.
- Affiliations
- Mayo Clinic (US)
- ORCID
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2007-10
- Volume
- 103
- Issue
- 4
- Pages
- 1136-1142
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2141022427
- Cited by
- 28
- References
- 36
- Citations by year
- 2026: 1 · 2025: 2 · 2018: 1 · 2015: 2 · 2014: 5 · 2013: 3 · 2012: 2
- FWCI
- 2.99
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (NS3 2352)
- National Center for Research Resources (K23 RR 17520, RR-00585, K23RR017520, M01RR000585)
- Topics
- Health Sciences › Medicine › Surgery › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
- Keywords
- postural orthostatic tachycardia syndrome, baroreflex sensitivity, rate control, exercise-induced tachycardia, arterial baroreflex, phenylephrine infusion, orthostatic tachycardia, pulse pressure variability, autonomic dysfunction
- MeSH terms
- Adult, Cardiac Output, Low, Cardiotonic Agents, Exercise Test, Female, Heart Rate, Hemodynamics, Humans, Male, Phenylephrine, Tachycardia, Exercise, Supine Position, Baroreflex
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review