The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
CORP: The assessment of total hemoglobin mass by carbon monoxide rebreathing
Abstract
In this Cores of Reproducibility in Physiology (CORP) article, we present the theory and practical aspects of the carbon monoxide (CO) rebreathing method for the determination of total hemoglobin mass in humans. With CO rebreathing, a small quantity of CO is diluted in O 2 and rebreathed for a specified time period, during which most of the CO is absorbed and bound to circulating hemoglobin. The dilution principle then allows calculation of the total number of circulating hemoglobin molecules based on the number of absorbed CO molecules and the resulting changes in the fraction of carboxyhemoglobin in blood. Total hemoglobin mass is derived by multiplication with the molar weight of hemoglobin. CO rebreathing has been used for >100 yr and has undergone steady improvement so that today excellent values in terms of accuracy and precision can be achieved if the methodological precautions are carefully followed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Mild CO intoxication symptoms (e.g., headache, fatigue) may occur at COHb concentrations >10%, with severe symptoms manifesting at COHb >20–25% (Siebenmann et al., 2017).”
From Low-dose carbon monoxide inhalation to increase total hemoglobin mass and endurance performance: scientific evidence and implications (2024) · cites this paper as Siebenmann et al., 2017
In the citing paper
“In research and clinical practice, low-dose CO is utilized as a tracer to assess lung diffusion capacity and total hemoglobin mass (tHb-mass) (Schmidt and Prommer, 2005; Siebenmann et al., 2017; Zavorsky and Smoliga, 2017; Amann, 2012; Robach et al., 2012; Nummela et al., 2021; Saunders et al., 2013).”
From Low-dose carbon monoxide inhalation to increase total hemoglobin mass and endurance performance: scientific evidence and implications (2024) · cites this paper as Siebenmann et al., 2017
In the citing paper
“The measurement of tHb by the CO rebreathing technique is a well-established method in exercise science (Siebenmann et al., 2017) and training practice.”
From Low-dose carbon monoxide inhalation to increase total hemoglobin mass and endurance performance: scientific evidence and implications (2024) · cites this paper as Siebenmann et al., 2017
In the citing paper
“During CO-rebreathing for tHb-mass determination COHb levels of up to 10% have been reported (Siebenmann et al., 2017);”
From Low-dose carbon monoxide inhalation to increase total hemoglobin mass and endurance performance: scientific evidence and implications (2024) · cites this paper as Siebenmann et al., 2017
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635
Intravenous iron supplementation in distance runners with low or suboptimal ferritin
GARVICAN, L. A., SAUNDERS, P. U., CARDOSO, T., MACDOUGALL, I. C., LOBIGS, L. M., FAZAKERLEY, R., FALLON, K. E., ANDERSON, B., ANSON, J. M., THOMPSON, K. G., et al. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182a53594 · Cited by 91
Research works printed but not linked: 53
- 10.1016/j.jsams.2010.07.007 · DOI
- 10.1111/j.1365-2141.1978.tb05810.x · DOI
- 10.1038/227386a0 · DOI
- 10.1007/s00421-014-2863-4 · DOI
- 10.1152/japplphysiol.00217.2003 · DOI
- 10.1152/jappl.1995.79.2.623 · DOI · Paper page
- 10.1152/japplphysiol.00624.2016 · DOI
- 10.1152/jappl.1974.37.2.247 · DOI
- 10.1111/cpf.12406 · DOI
- 10.1006/bcmd.1996.0024 · DOI
- 10.1097/MAJ.0b013e318063c707 · DOI
- 10.1111/j.1600-0838.2010.01145.x · DOI
- 10.1113/expphysiol.2010.054031 · DOI
- 10.1097/JSM.0b013e3181ddcd5b · DOI
- 10.1159/000192905 · DOI
- 10.1016/j.jen.2007.11.014 · DOI
- 10.1249/01.mss.0000222848.35004.41 · DOI
- 10.1152/japplphysiol.00505.2005 · DOI
- 10.1113/jphysiol.1895.sp000578 · DOI
- 10.1113/jphysiol.1900.sp000800 · DOI
- 10.1152/physrev.1985.65.1.149 · DOI
- 10.1249/MSS.0000000000000808 · DOI
- International Committee for Standardization in Haematology, 1980, J Nucl Med, 21, 793
- 10.1152/japplphysiol.00740.2006 · DOI
- 10.1249/MSS.0000000000000729 · DOI
- 10.1152/ajpheart.00138.2015 · DOI
- 10.1080/00365513.2016.1271908 · DOI
- 10.1007/s00421-013-2681-0 · DOI
- 10.1007/s00421-009-1259-3 · DOI
- 10.1113/jphysiol.2006.122689 · DOI
- 10.1152/ajpregu.00012.2017 · DOI
- 10.1113/JP270250 · DOI
- Naef N, Int J Sports Med
- 10.1111/j.1751-7133.2010.00208.x · DOI
- Olson K, 2008, BMJ Clin Evid, 2008, 2103
- 10.1093/bja/aew445 · DOI
- 10.1249/mss.0b013e318123e8a6 · DOI
- 10.1007/s00421-007-0439-2 · DOI
- 10.1249/MSS.0b013e31829047e5 · DOI
- Retzlaff JA, 1969, Blood, 33, 649, 10.1182/blood.V33.5.649.649 · DOI
- 10.1152/ajpregu.00226.2002 · DOI · Paper page
- 10.1097/00005768-200002000-00012 · DOI
- 10.1249/00005768-199204000-00009 · DOI
- 10.1007/s00421-005-0050-3 · DOI · Paper page
- 10.1152/japplphysiol.01121.2014 · DOI · Paper page
- 10.1152/japplphysiol.00388.2011 · DOI
- 10.2165/00007256-200232060-00002 · DOI
- 10.1146/annurev.pa.15.040175.002205 · DOI
- 10.1080/00365519109091106 · DOI
- 10.1161/01.RES.79.3.581 · DOI
- 10.1378/chest.117.3.801 · DOI · Paper page
- 10.1124/pr.57.4.3 · DOI
- 10.1046/j.1365-2257.2001.00388.x · DOI
Cited by
Gatterer, H., Dünnwald, T., Woyke, S., Faulhaber, M., Schumacher, Y. O., & Schobersberger, W. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1490205 · Cited by 13
Villanova, S., Porcelli, S., Ekström, L., & Cardinale, D. A. (2026) · Experimental Physiology · doi:10.1113/ep093005 · Cited by 5
Tobacco smoking: A stimulus for blood volume expansion
Sotiridis, A., Dardamanis-Aidonas, C., Makris, A., Loukas, I., Geladas, N., & Koskolou, M. (2026) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2025.104505 · Cited by 1
Metadata
- Authors
- Siebenmann, C., Keiser, S., Robach, P., & Lundby, C.
- Affiliations
- The Centre for Physical Activity Research, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark;
- Center for Integrative Human Physiology, Institute of Physiology, University of Zürich, Zürich, Switzerland; and
- National School for Mountain Sports, Site of the National School for Skiing and Mountaineering (ENSA), Chamonix, France
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2017-09-01
- Volume
- 123
- Issue
- 3
- Pages
- 645-654
- ISSN
- 8750-7587
- 1522-1601
- Cited by
- 133
- References
- 2
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CORP: The assessment of total hemoglobin mass by carbon monoxide rebreathing. https://app.cochat.ai/papers/10.1152/japplphysiol.00185.2017
- The paper
- Siebenmann, C., Keiser, S., Robach, P., & Lundby, C. (2017). CORP: The assessment of total hemoglobin mass by carbon monoxide rebreathing. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00185.2017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.