The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
The effect of surface electrical stimulation on hyolaryngeal movement in normal individuals at rest and during swallowing
Abstract
Surface electrical stimulation is currently used in therapy for swallowing problems, although little is known about its physiological effects on neck muscles or swallowing. Previously, when one surface electrode placement was used in dysphagic patients at rest, it lowered the hyolaryngeal complex. Here we examined the effects of nine other placements in normal volunteers to determine 1) whether movements induced by surface stimulation using other placements differ, and 2) whether lowering the hyolaryngeal complex by surface electrical stimulation interfered with swallowing in healthy adults. Ten bipolar surface electrode placements overlying the submental and laryngeal regions were tested. Maximum tolerated stimulation levels were applied at rest while participants held their mouths closed. Videofluoroscopic recordings were used to measure hyoid bone and subglottic air column (laryngeal) movements from resting position and while swallowing 5 ml of liquid barium, with and without stimulation. Videofluoroscopic recordings of swallows were rated blind to condition using the National Institutes of Health-Swallowing Safety Scale. Significant (P < 0.0001) laryngeal and hyoid descent occurred with stimulation at rest. During swallowing, significant (P ≤ 0.01) reductions in both the larynx and hyoid bone peak elevation occurred during stimulated swallows. The stimulated swallows were also judged less safe than nonstimulated swallows using the National Institutes of Health-Swallowing Safety Scale (P = 0.0275). Because surface electrical stimulation reduced hyolaryngeal elevation during swallowing in normal volunteers, our findings suggest that surface electrical stimulation will reduce elevation during swallowing therapy for dysphagia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mixed-Effects Models in Sand S-PLUS
Pinheiro, J. C., & Bates, D. M. (2000) · Statistics and Computing · doi:10.1007/978-1-4419-0318-1 · Cited by 11,187
Mixed-Effects Models in S and S-PLUS
(2001) · Technometrics · doi:10.1198/tech.2001.s574 · Cited by 9,278
Mixed-Effects Models in S and S-PLUS
(2000) · Statistics and Computing · doi:10.1007/b98882 · Cited by 930
Cited by
Robbins, J., Butler, S. G., Daniels, S. K., Diez Gross, R., Langmore, S., Lazarus, C. L., Martin-Harris, B., McCabe, D., Musson, N., & Rosenbek, J. (2008) · Journal of Speech, Language, and Hearing Research · doi:10.1044/1092-4388(2008/021 · Cited by 253
Metadata
- Authors
- Humbert, I. A., Poletto, C. J., Saxon, K. G., Kearney, P. R., Crujido, L., Wright-Harp, W., Payne, J., Jeffries, N., Sonies, B. C., & Ludlow, C. L.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2006-12
- Volume
- 101
- Issue
- 6
- Pages
- 1657-1663
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2119290887
- Cited by
- 187
- References
- 3
- FWCI
- 13.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.