Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 670

The DOI matches its Crossref record.

An in vivo microanalytical technique for measuring the local biochemical milieu of human skeletal muscle

Shah, Jay P., Phillips, Terry M., Danoff, Jerome V., Gerber, Lynn H.·2005·Journal of Applied Physiology

Abstract

Myofascial pain associated with myofascial trigger points (MTrPs) is a common cause of nonarticular musculoskeletal pain. Although the presence of MTrPs can be determined by soft tissue palpation, little is known about the mechanisms and biochemical milieu associated with persistent muscle pain. A microanalytical system was developed to measure the in vivo biochemical milieu of muscle in near real time at the subnanogram level of concentration. The system includes a microdialysis needle capable of continuously collecting extremely small samples (∼0.5 μl) of physiological saline after exposure to the internal tissue milieu across a 105-μm-thick semi-permeable membrane. This membrane is positioned 200 μm from the tip of the needle and permits solutes of <75 kDa to diffuse across it. Three subjects were selected from each of three groups (total 9 subjects): normal (no neck pain, no MTrP); latent (no neck pain, MTrP present); active (neck pain, MTrP present). The microdialysis needle was inserted in a standardized location in the upper trapezius muscle. Due to the extremely small sample size collected by the microdialysis system, an established microanalytical laboratory, employing immunoaffinity capillary electrophoresis and capillary electrochromatography, performed analysis of selected analytes. Concentrations of protons, bradykinin, calcitonin gene-related peptide, substance P, tumor necrosis factor-α, interleukin-1β, serotonin, and norepinephrine were found to be significantly higher in the active group than either of the other two groups ( P < 0.01). pH was significantly lower in the active group than the other two groups ( P < 0.03). In conclusion, the described microanalytical technique enables continuous sampling of extremely small quantities of substances directly from soft tissue, with minimal system perturbation and without harmful effects on subjects. The measured levels of analytes can be used to distinguish clinically distinct groups.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00419.2005

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 670

Metadata

Authors
Shah, J. P., Phillips, T. M., Danoff, J. V., & Gerber, L. H.
Venue
Journal of Applied Physiology
Published
2005-11
Volume
99
Issue
5
Pages
1977-1984
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2077193290
Cited by
670
References
0
FWCI
14.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An in vivo microanalytical technique for measuring the local biochemical milieu of human skeletal muscle. https://app.cochat.ai/papers/10.1152/japplphysiol.00419.2005
The paper
Shah, J. P., Phillips, T. M., Danoff, J. V., & Gerber, L. H. (2005). An in vivo microanalytical technique for measuring the local biochemical milieu of human skeletal muscle. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00419.2005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.