An artificial neural network model of energy expenditure using nonintegrated acceleration signals
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Accelerometers are a promising tool for characterizing physical activity patterns in free living. The major limitation in their widespread use to date has been a lack of precision in estimating energy expenditure (EE), which may be attributed to the oversimplified time-integrated acceleration signals and subsequent use of linear regression models for EE estimation. In this study, we collected biaxial raw (32 Hz) acceleration signals at the hip to develop a relationship between acceleration and minute-to-minute EE in 102 healthy adults using EE data collected for nearly 24 h in a room calorimeter as the reference standard. From each 1 min of acceleration data, we extracted 10 signal characteristics (features) that we felt had the potential to characterize EE intensity. Using these data, we developed a feed-forward/back-propagation artificial neural network (ANN) model with one hidden layer (12 × 20 × 1 nodes). Results of the ANN were compared with estimations using the ActiGraph monitor, a uniaxial accelerometer, and the IDEEA monitor, an array of five accelerometers. After training and validation (leave-one-subject out) were completed, the ANN showed significantly reduced mean absolute errors (0.29 ± 0.10 kcal/min), mean squared errors (0.23 ± 0.14 kcal 2/min 2), and difference in total EE (21 ± 115 kcal/day), compared with both the IDEEA ( P < 0.01) and a regression model for the ActiGraph accelerometer ( P < 0.001). Thus ANN combined with raw acceleration signals is a promising approach to link body accelerations to EE. Further validation is needed to understand the performance of the model for different physical activity types under free-living conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Activity Recognition from User-Annotated Acceleration Data
Bao, L., & Intille, S. S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24646-6_1 · Cited by 3,147
Integration of physiological and accelerometer data to improve physical activity assessment
STRATH, S. J., BRAGE, S., & EKELUND, U. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185650.68232.3f · Cited by 126 · cited 1×
“This effort has included adding additional acceleration dimensions at the hip (8, 20), adding sensors to the limbs (wrist and ankle) for more complete movement detection (8, 15), and coupling physical and physiological information, such as heart rate, near body temperature, and skin impedance (6, 16, 22).”
Method
Cited by
Medicine & science in sports & exercise
(1994) · Journal of the American Dietetic Association · doi:10.1016/0002-8223(94)92575-5 · Cited by 1,303
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Machine Learning Methods for Classifying Human Physical Activity from On-Body Accelerometers
Mannini, A., & Sabatini, A. M. (2010) · Sensors · doi:10.3390/s100201154 · Cited by 781
Best Practices for Using Physical Activity Monitors in Population-Based Research
MATTHEWS, C. E., HAGSTRÖMER, M., POBER, D. M., & BOWLES, H. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399e5b · Cited by 703
Assessment of physical activity in youth
Corder, K., Ekelund, U., Steele, R. M., Wareham, N. J., & Brage, S. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00094.2008 · Cited by 581
Metadata
- Authors
- Rothney, M. P., Neumann, M., Béziat, A., & Chen, K. Y.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2007-10
- Volume
- 103
- Issue
- 4
- Pages
- 1419-1427
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2138934389
- Cited by
- 144
- References
- 3
- FWCI
- 13.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An artificial neural network model of energy expenditure using nonintegrated acceleration signals. https://app.cochat.ai/papers/10.1152/japplphysiol.00429.2007
- The paper
- Rothney, M. P., Neumann, M., Béziat, A., & Chen, K. Y. (2007). An artificial neural network model of energy expenditure using nonintegrated acceleration signals. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00429.2007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.