Technical and physiological background of plasma volume measurement with indocyanine green: a clarification of misunderstandings
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The indocyanine green (ICG) dilution technique (DT) is frequently used for plasma volume (PV) measurement. However, because of inadequate knowledge about the properties of this dye, lack of accuracy has been attributed to the method. The aim of this report is to provide physiological background information about the ICG-DT to avoid some profound misunderstandings. When performing tracer dilution, one has to consider the tracer's distribution space before interpreting the result. For ICG, the distribution space is the total PV, i.e., circulating + noncirculating PV, fixed within the endothelial glycocalyx. The distribution space of red blood cells and large molecules, in contrast, is only the circulating part of PV. Therefore, it is erroneous to compare directly PV derived from different tracer dilution methods. The transcapillary escape rate of ICG should not relevantly influence measured PV if the method is performed properly, i.e., if a short time window of measurement is subjected to monoexponential extrapolation. A major problem of PV measurement in general is that the target itself is very inconstant. Thus, checking for constancy of ICG-DT with two consecutive measurements is unreliable. Nevertheless, the ICG-DT is a useful tool for determining PV, provided it is well understood by the investigator to enable correct interpretation of the results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
INCREASED VASCULAR PERMEABILITY: A MAJOR CAUSE OF HYPOALBUMINAEMIA IN DISEASE AND INJURY
Fleck, A., Hawker, F., Wallace, P. I., Raines, G., Trotter, J., Ledingham, I. M., & Calman, K. C. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91447-3 · Cited by 898 · cited 2×
“25% under the worst clinical conditions (9).”
Background
Cited by
A Rational Approach to Perioperative Fluid Management
Chappell, D., Jacob, M., Hofmann-Kiefer, K., Conzen, P., & Rehm, M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e3181863117 · Cited by 909
Self-citationWoodcock, T. E., & Woodcock, T. M. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aer515 · Cited by 806
Rehm, M., Bruegger, D., Christ, F., Conzen, P., Thiel, M., Jacob, M., Chappell, D., Stoeckelhuber, M., Welsch, U., Reichart, B., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.684852 · Cited by 669
Self-citationEndothelial glycocalyx and coronary vascular permeability: the fringe benefit
Becker, B. F., Chappell, D., & Jacob, M. (2010) · Basic Research in Cardiology · doi:10.1007/s00395-010-0118-z · Cited by 277
Self-citationSha, S., Polidori, D., Heise, T., Natarajan, J., Farrell, K., Wang, S. ‐., Sica, D., Rothenberg, P., & Plum‐Mörschel, L. (2014) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.12322 · Cited by 249
“An additional advantage of the ICG method is the short biological half-life (∼3 min) of the dye, which enables repeated tests within a short period of time [20,21].”
Method
Metadata
- Authors
- Jacob, M., Conzen, P., Finsterer, U., Krafft, A., Becker, B. F., & Rehm, M.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2007-03
- Volume
- 102
- Issue
- 3
- Pages
- 1235-1242
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1975504264
- Cited by
- 67
- References
- 1
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.