Precooling leg muscle improves intermittent sprint exercise performance in hot, humid conditions
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We used three techniques of precooling to test the hypothesis that heat strain would be alleviated, muscle temperature (T mu) would be reduced, and as a result there would be delayed decrements in peak power output (PPO) during exercise in hot, humid conditions. Twelve male team-sport players completed four cycling intermittent sprint protocols (CISP). Each CISP consisted of twenty 2-min periods, each including 10 s of passive rest, 5 s of maximal sprint against a resistance of 7.5% body mass, and 105 s of active recovery. The CISP, preceded by 20 min of no cooling (Control), precooling via an ice vest (Vest), cold water immersion (Water), and ice packs covering the upper legs (Packs), was performed in hot, humid conditions (mean ± SE; 33.7 ± 0.3°C, 51.6 ± 2.2% relative humidity) in a randomized order. The rate of heat strain increase during the CISP was faster in Control than Water and Packs ( P < 0.01), but it was similar to Vest. Packs and Water blunted the rise of T mu until minute 16 and for the duration of the CISP (40 min), respectively ( P < 0.01). Reductions in PPO occurred from minute 32 onward in Control, and an increase in PPO by ∼4% due to Packs was observed (main effect; P < 0.05). The method of precooling determined the extent to which heat strain was reduced during intermittent sprint cycling, with leg precooling offering the greater ergogenic effect on PPO than either upper body or whole body cooling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of muscle temperature on leg extension force and short-term power output in humans
Sargeant, A. J. (1987) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00424812 · Cited by 370
Comparison of two cool vests on heat-strain reduction while wearing a firefighting ensemble
Bennett, B. L., Hagan, R. D., Huey, K. A., Minson, C., & Cain, D. (1995) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00865029 · Cited by 94
Cited by
Périard, J. D., Eijsvogels, T. M. H., & Daanen, H. A. M. (2021) · Physiological Reviews · doi:10.1152/physrev.00038.2020 · Cited by 647
Warm-Up Strategies for Sport and Exercise: Mechanisms and Applications
McGowan, C. J., Pyne, D. B., Thompson, K. G., & Rattray, B. (2015) · Sports Medicine · doi:10.1007/s40279-015-0376-x · Cited by 579
Noakes, T. D. (2012) · Frontiers in Physiology · doi:10.3389/fphys.2012.00082 · Cited by 501
Consensus recommendations on training and competing in the heat
Racinais, S., Alonso, J. M., Coutts, A. J., Flouris, A. D., Girard, O., González-Alonso, J., Hausswirth, C., Jay, O., Lee, J. K. W., Mitchell, N., et al. (2015) · British Journal of Sports Medicine · doi:10.1136/bjsports-2015-094915 · Cited by 346
Noakes, T. D. (2011) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h10-082 · Cited by 275
Metadata
- Authors
- Castle, P. C., Macdonald, A. L., Philp, A., Webborn, A., Watt, P. W., & Maxwell, N. S.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2006-04
- Volume
- 100
- Issue
- 4
- Pages
- 1377-1384
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2170337369
- Cited by
- 156
- References
- 2
- FWCI
- 2.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.