CoChat

Ultrasound imaging to assess skeletal muscle architecture during movements: a systematic review of methods, reliability, and challenges

Open access
Van Hooren, Bas, Teratsias, Panayiotis, Hodson-Tole, Emma F. · 2020 · Journal of Applied Physiology
Cited by 117

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

B-mode ultrasound is often used to quantify muscle architecture during movements. Our objectives were to 1) systematically review the reliability of fascicle length (FL) and pennation angles (PA) measured using ultrasound during movements involving voluntary contractions; 2) systematically review the methods used in studies reporting reliability, discuss associated challenges, and provide recommendations to improve the reliability and validity of dynamic ultrasound measurements; and 3) provide an overview of computational approaches for quantifying fascicle architecture, their validity, agreement with manual quantification of fascicle architecture, and advantages and drawbacks. Three databases were searched until June 2019. Studies among healthy human individuals aged 17–85 yr that investigated the reliability of FL or PA in lower-extremity muscles during isoinertial movements and that were written in English were included. Thirty studies ( n = 340 participants) were included for reliability analyses. Between-session reliability as measured by coefficient of multiple correlations (CMC), and coefficient of variation (CV) was FL CMC: 0.89–0.96; CV: 8.3% and PA CMC: 0.87–0.90; CV: 4.5–9.6%. Within-session reliability was FL CMC: 0.82–0.99; CV: 0.0–6.7% and PA CMC: 0.91; CV: 0.0–15.0%. Manual analysis reliability was FL CMC: 0.89–0.96; CV: 0.0–15.9%; PA CMC: 0.84–0.90; and CV: 2.0–9.8%. Computational analysis FL CMC was 0.82–0.99, and PA CV was 14.0–15.0%. Eighteen computational approaches were identified, and these generally showed high agreement with manual analysis and high validity compared with phantoms or synthetic images. B-mode ultrasound is a reliable method to quantify fascicle architecture during movement. Additionally, computational approaches can provide a reliable and valid estimation of fascicle architecture.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00835.2019

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 117

Metadata

Authors
Van Hooren, B., Teratsias, P., & Hodson-Tole, E. F.
Venue
Journal of Applied Physiology
Published
2020-04-01
Volume
128
Issue
4
Pages
978-999
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W3011941870
Cited by
117
References
3
FWCI
2.88
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasound imaging to assess skeletal muscle architecture during movements: a systematic review of methods, reliability, and challenges. https://app.cochat.ai/papers/10.1152/japplphysiol.00835.2019
The paper
Van Hooren, B., Teratsias, P., & Hodson-Tole, E. F. (2020). Ultrasound imaging to assess skeletal muscle architecture during movements: a systematic review of methods, reliability, and challenges. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00835.2019

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.