The DOI matches its Crossref record.
Influences of head positions and bite opening on collapsibility of the passive pharynx
Abstract
A collapsible tube surrounded by soft material within a rigid box was proposed as a two-dimensional mechanical model for the pharyngeal airway. This model predicts that changes in the box size (pharyngeal bony enclosure size anatomically defined as cross-sectional area bounded by the inside edge of bony structures such as the mandible, maxilla, and spine, and being perpendicular to the airway) influence patency of the tube. We examined whether changes in the bony enclosure size either with head positioning or bite opening influence collapsibility of the pharyngeal airway. Static mechanical properties of the passive pharynx were evaluated in anesthetized, paralyzed patients with sleep-disordered breathing before and during neck extension with bite closure ( n = 11), neck flexion with bite closure ( n = 9), and neutral neck position with bite opening ( n = 11). Neck extension significantly increased maximum oropharyngeal airway size and decreased closing pressures of the velopharynx and oropharynx. Notably, neck extension significantly decreased compliance of the oropharyngeal airway wall. Neck flexion and bite opening decreased maximum oropharyngeal airway size and increased closing pressure of the velopharynx and oropharynx. Our results indicate the importance of neck and mandibular position for determining patency and collapsibility of the passive pharynx.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidelines for the management of tracheal intubation in critically ill adults
Higgs, A., McGrath, B. A., Goddard, C., Rangasami, J., Suntharalingam, G., Gale, R., & Cook, T. M. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.10.021 · Cited by 900
ISONO, S. (2012) · Respirology · doi:10.1111/j.1440-1843.2011.02093.x · Cited by 272
Self-citationSupine position related obstructive sleep apnea in adults: Pathogenesis and treatment
Joosten, S. A., O'Driscoll, D. M., Berger, P. J., & Hamilton, G. S. (2014) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2013.01.005 · Cited by 259
Marked reduction in obstructive sleep apnea severity in slow wave sleep
Ratnavadivel, R., Chau, N., Stadler, D., Yeo, A., McEvoy, R. D., & Catcheside, P. G. (2009) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27651 · Cited by 207
Tracheal Traction Effects on Upper Airway Patency in Rabbits: The Role of Tissue Pressure
Kairaitis, K., Byth, K., Parikh, R., Stavrinou, R., Wheatley, J. R., & Amis, T. C. (2007) · Sleep · doi:10.1093/sleep/30.2.179 · Cited by 125
Li, Y., Lin, N., Ye, J., Chang, Q., Han, D., & Sperry, A. (2012) · Respiratory Care · doi:10.4187/respcare.00929 · Cited by 84
Structural effectiveness of pharyngeal sleep apnea surgery
Tucker Woodson, B. (2008) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2008.07.010 · Cited by 46
Metadata
- Authors
- Isono, S., Tanaka, A., Tagaito, Y., Ishikawa, T., & Nishino, T.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2004-07
- Volume
- 97
- Issue
- 1
- Pages
- 339-346
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2149350222
- Cited by
- 161
- References
- 0
- FWCI
- 3.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.