Influence of tendon slack on electromechanical delay in the human medial gastrocnemius in vivo
The DOI matches its Crossref record.
Abstract
The purpose of this study was to clarify the influence of muscle-tendon complex stretch on electromechanical delay (EMD) in terms of the extent of tendon slack in the human medial gastrocnemius (MG). EMD and MG tendon length were measured at each of five ankle joint angles (-30, -20, -10, 0, and 5°: positive values for dorsiflexion) using percutaneous electrical stimulation and ultrasonography, respectively. The extent of MG tendon slack was calculated as MG tendon length shortening, standardized with MG tendon slack length obtained at the joint angle (-16° ± 5°) where the passive ankle joint torque was zero. EMD at -30° (19.2 ±2.2 ms) and -20° (17.2 ± 1.3 ms) was significantly greater than that at -10° (16.0 ±2.3 ms), 0° (15.0 ±1.4 ms), and 5° (14.8 ±1.4 ms), and at 0 and 5°, respectively. The relative EMD, normalized with the maximal EMD for each subject, decreased dependent on the extent of decrease in MG tendon slack. There were no significant differences in EMD among the joint angles (-10, 0, and 5°) where MG tendon slack was taken up. These results suggest that the extent of tendon slack is an important factor for determining EMD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Methodological aspects of SEMG recordings for force estimation – A tutorial and review
Staudenmann, D., Roeleveld, K., Stegeman, D. F., & van Dieën, J. H. (2010) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2009.08.005 · Cited by 379
Neuromuscular Performance of Explosive Power Athletes versus Untrained Individuals
TILLIN, N. A., JIMENEZ-REYES, P., PAIN, M. T. G., & FOLLAND, J. P. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181be9c7e · Cited by 284
“, tendon slack (29, 43) and compliance (22)).”
De Boer, M. D., Maganaris, C. N., Seynnes, O. R., Rennie, M. J., & Narici, M. V. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2007.135392 · Cited by 283
Maïsetti, O., Hug, F., Bouillard, K., & Nordez, A. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.01.009 · Cited by 263
de Ruiter, C. J., Kooistra, R. D., Paalman, M. I., & de Haan, A. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00230.2004 · Cited by 222
“shown for human medial gastrocnemius muscle (26).”
Metadata
- Authors
- Muraoka, T., Muramatsu, T., Fukunaga, T., & Kanehisa, H.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2004-02
- Volume
- 96
- Issue
- 2
- Pages
- 540-544
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2048878963
- Cited by
- 144
- References
- 0
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of tendon slack on electromechanical delay in the human medial gastrocnemius in vivo. https://app.cochat.ai/papers/10.1152/japplphysiol.01015.2002
- The paper
- Muraoka, T., Muramatsu, T., Fukunaga, T., & Kanehisa, H. (2004). Influence of tendon slack on electromechanical delay in the human medial gastrocnemius in vivo. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.01015.2002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.