CoChat

Psychrometric limits and critical evaporative coefficients for unacclimated men and women

Kenney, W. Larry, Zeman, Michael J. · 2002 · Journal of Applied Physiology
Cited by 79

The DOI matches its Crossref record.

Abstract

Critical environmental limits, defined as those above which heat balance cannot be maintained for a given metabolic heat production, have not been determined for unacclimated subjects. To characterize critical environmental limits and to derive evaporative heat exchange coefficients ( K e′) for unacclimated young men ( n = 11) and women ( n = 10), subjects of average aerobic fitness walked at 30% maximal aerobic capacity in an environmental chamber. Critical environmental conditions were defined as the psychrometric loci of dry-bulb temperature and water vapor pressure at which core (esophageal) temperature was forced out of equilibrium (heat gain exceeded heat loss). Compared with the men in our study, the women had significantly higher critical environmental limits ( P < 0.001) in warm (34–38°C), humid (>60%) environments, a function of their lower absolute metabolic heat production at the fixed relative exercise intensity. Isotherms constructed from biophysical models closely fit the data in this range of environments but underestimated empirically determined critical limits in hotter, drier environments. Sex-specific values of K e′ were derived by partial calorimetry in the critical water vapor pressure environments, in which full skin wettedness occurred. There were no sex differences for K e′ (men = 17.4, 15.5, and 14.2 W · m−2 · Torr−1 and women = 16.8, 15.5, and 14.2 W · m−2 · Torr−1 at 34, 36, and 38°C, respectively). These K e′ values were lower than those previously published for fully heat-acclimated men (18.4 W · m−2 · Torr−1 at 36°C) and women (17.7 W · m−2 · Torr−1 at 36°C and 15.5 W · m−2 · Torr−1 at 38°C) and may be used to model heat balance responses for unacclimated men and women working in hot environments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.01040.2001

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 79

Metadata

Authors
Kenney, W. L., & Zeman, M. J.
Venue
Journal of Applied Physiology
Published
2002-06-01
Volume
92
Issue
6
Pages
2256-2263
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W1974963519
Cited by
79
References
0
FWCI
0.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Psychrometric limits and critical evaporative coefficients for unacclimated men and women. https://app.cochat.ai/papers/10.1152/japplphysiol.01040.2001
The paper
Kenney, W. L., & Zeman, M. J. (2002). Psychrometric limits and critical evaporative coefficients for unacclimated men and women. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.01040.2001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.