Regional lung perfusion estimated by electrical impedance tomography in a piglet model of lung collapse
The DOI matches its Crossref record.
Abstract
The assessment of the regional match between alveolar ventilation and perfusion in critically ill patients requires simultaneous measurements of both parameters. Ideally, assessment of lung perfusion should be performed in real-time with an imaging technology that provides, through fast acquisition of sequential images, information about the regional dynamics or regional kinetics of an appropriate tracer. We present a novel electrical impedance tomography (EIT)-based method that quantitatively estimates regional lung perfusion based on first-pass kinetics of a bolus of hypertonic saline contrast. Pulmonary blood flow was measured in six piglets during control and unilateral or bilateral lung collapse conditions. The first-pass kinetics method showed good agreement with the estimates obtained by single-photon-emission computerized tomography (SPECT). The mean difference (SPECT minus EIT) between fractional blood flow to lung areas suffering atelectasis was −0.6%, with a SD of 2.9%. This method outperformed the estimates of lung perfusion based on impedance pulsatility. In conclusion, we describe a novel method based on EIT for estimating regional lung perfusion at the bedside. In both healthy and injured lung conditions, the distribution of pulmonary blood flow as assessed by EIT agreed well with the one obtained by SPECT. The method proposed in this study has the potential to contribute to a better understanding of the behavior of regional perfusion under different lung and therapeutic conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Personalized mechanical ventilation in acute respiratory distress syndrome
Pelosi, P., Ball, L., Barbas, C. S. V., Bellomo, R., Burns, K. E. A., Einav, S., Gattinoni, L., Laffey, J. G., Marini, J. J., Myatra, S. N., et al. (2021) · Critical Care · doi:10.1186/s13054-021-03686-3 · Cited by 217
“Technological development by EIT may also quantitatively estimate regional lung perfusion based on first-pass kinetics of a bolus of hypertonic saline contrast [74, 75].”
BackgroundElectrical impedance tomography in acute respiratory distress syndrome
Bachmann, M. C., Morais, C., Bugedo, G., Bruhn, A., Morales, A., Borges, J. B., Costa, E., & Retamal, J. (2018) · Critical Care · doi:10.1186/s13054-018-2195-6 · Cited by 204
Self-citationYoshida, T., Roldan, R., Beraldo, M. A., Torsani, V., Gomes, S., De Santis, R. R., Costa, E. L. V., Tucci, M. R., Lima, R. G., Kavanagh, B. P., et al. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000001649 · Cited by 185
“We performed EIT perfusion analysis based on the first pass kinetics method as previously described (20).”
MethodSelf-citationElectrical Impedance Tomography for Cardio-Pulmonary Monitoring
Putensen, C., Hentze, B., Muenster, S., & Muders, T. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8081176 · Cited by 160
“[64] found a correlation of lung perfusion from EIT with SPECT using hypertonic saline (NaCl 20%, 10 mL) in healthy subjects with unilateral lung collapse and injured subjects with bilateral-dependent lung collapse.”
BackgroundMethodInfluentialHemodynamic monitoring in the era of digital health
Michard, F. (2016) · Annals of Intensive Care · doi:10.1186/s13613-016-0119-7 · Cited by 57
Metadata
- Authors
- Borges, J. B., Suarez-Sipmann, F., Bohm, S. H., Tusman, G., Melo, A., Maripuu, E., Sandström, M., Park, M., Costa, E. L. V., Hedenstierna, G., & Amato, M.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2012-01-01
- Volume
- 112
- Issue
- 1
- Pages
- 225-236
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2155235791
- Cited by
- 222
- References
- 0
- FWCI
- 6.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.