Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 225

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Relationship between middle cerebral artery blood velocity and end-tidal PCO2 in the hypocapnic-hypercapnic range in humans

Ide, Kojiro, Eliasziw, Michael, Poulin, Marc J.·2003·Journal of Applied Physiology

Abstract

This study examined the relationship between cerebral blood flow (CBF) and end-tidal Pco 2 (Pet CO 2) in humans. We used transcranial Doppler ultrasound to determine middle cerebral artery peak blood velocity responses to 14 levels of Pet CO 2 in a range of 22 to 50 Torr with a constant end-tidal Po 2 (100 Torr) in eight subjects. Pet CO 2 and end-tidal Po 2 were controlled by using the technique of dynamic end-tidal forcing combined with controlled hyperventilation. Two protocols were conducted in which Pet CO 2 was changed by 2 Torr every 2 min from hypocapnia to hypercapnia ( protocol I) and vice-versa ( protocol D). Over the range of Pet CO 2 studied, the sensitivity of peak blood velocity to changes in Pet CO 2 (CBF-Pet CO 2 sensitivity) was nonlinear with a greater sensitivity in hypercapnia (4.7 and 4.0%/Torr, protocols I and D, respectively) compared with hypocapnia (2.5 and 2.2%/Torr). Furthermore, there was evidence of hysteresis in the CBF-Pet CO 2 sensitivity; for a given Pet CO 2, there was greater sensitivity during protocol I compared with protocol D. In conclusion, CBF-Pet CO 2 sensitivity varies depending on the level of Pet CO 2 and the protocol that is used. The mechanisms underlying these responses require further investigation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.01186.2002

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 225

Metadata

Authors
Ide, K., Eliasziw, M., & Poulin, M. J.
Venue
Journal of Applied Physiology
Published
2003-07
Volume
95
Issue
1
Pages
129-137
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W1946411541
Cited by
225
References
1
FWCI
5.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.