Near-infrared spectroscopy (NIRS) with the tracer indocyanine green (ICG) may be used for measuring muscle blood flow (MBF) during exercise, if arterial ICG concentration is measured simultaneously. Although pulse dye densitometry allows for noninvasive measurement of arterial dye concentration, this technique is sensitive to motion and may not be applicable during exercise. The aim of this study was to evaluate a noninvasive blood flow index (BFI), which is derived solely from the muscle ICG concentration curve. In 10 male cyclists 5 mg ICG were injected into an antecubital vein at rest and during cycling at 30, 60, 70, 80, 90, and 100% of previously determined maximal work load. Simultaneously blood was withdrawn through a photodensitometer at 20 ml/min from the radial artery to measure arterial ICG concentration. To measure muscle tissue ICG concentrations, two sets of NIRS optodes were positioned on the skin, one over the left seventh intercostal space and the other over the left vastus lateralis muscle. MBF was calculated from the arterial and muscle concentration data according to Fick's principle. BFI was calculated solely from the muscle concentration curve as ICG concentration difference divided by rise time between 10 and 90% of peak. During exercise mean BFI values changed similarly to MBF in both intercostal and quadriceps muscles and showed excellent correlations with MBF: r = 0.98 and 0.96, respectively. Individual data showed some scattering among BFI and MBF values but still reasonable correlations of BFI with MBF: r = 0.73 and 0.72 for intercostal and quadriceps muscles, respectively. Interobserver variability, as analyzed by Bland-Altman plots, was considerably less for BFI than MBF. These data suggest that BFI can be used for measuring changes in muscle perfusion from rest to maximal exercise. Although absolute blood flow cannot be determined, BFI has the advantages of being essentially noninvasive and having low interobserver variability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.01269.2009

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 62

Metadata

Authors
Habazettl, H., Athanasopoulos, D., Kuebler, W. M., Wagner, H., Roussos, C., Wagner, P. D., Ungruhe, J., Zakynthinos, S., & Vogiatzis, I.
Venue
Journal of Applied Physiology
Published
2010-04
Volume
108
Issue
4
Pages
962-967
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2139180850
Cited by
62
References
1
FWCI
4.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.