Cited by 219Muscle activation and electromyography studiesMuscle Physiology and DisordersCardiovascular and exercise physiology

Firing rates of motor units in human vastus lateralis muscle during fatiguing isometric contractions

Adam, Alexander, De Luca, Carlo J.·2005·Journal of Applied Physiology

Abstract

We investigated the firing rate of motor units in the vastus lateralis muscle in five healthy young men (mean = 21.4 yr, SD = 0.9) during a sequence of isometric constant-torque contractions repeated to exhaustion. The contractions were sustained at 20% of the maximal voluntary level, measured at the beginning of the test sequence. Electromyographic (EMG) signals were recorded via quadrifilar fine-wire electrodes and subsequently decomposed into their constituent motor unit action potentials to obtain the motor unit firing times. In addition, we measured the whole muscle mechanical properties during the fatigue task using electrical stimulation. The firing rate of motor units first decreased within the first 10–20% of the endurance time of the contractions and then increased. The firing rate increase was accompanied by recruitment of additional motor units as the force output remained constant. The elicited twitch and tetanic torque responses first increased and then decreased. The two processes modulated in a complementary fashion at the same time. Our data suggest that, when the vastus lateralis muscle is activated to maintain a constant torque output, its motoneuron pool receives a net excitatory drive that first decreases to compensate for the short-lived potentiation of the muscle force twitch and then increases to compensate for the diminution of the force twitch. The underlying inverse relationship between the firing rate and the recruitment threshold that has been reported for nonfatigued contractions is maintained. We, therefore, conclude that the central nervous system control of vastus lateralis motor units remains invariant during fatigue in submaximal isometric isotonic contractions.

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.01344.2004

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Discharges with interdischarge intervals < 33.3 or >250 ms were excluded because firing rates calculated from this range are unusually high (>30 Hz) or low (<4 Hz) for the VL muscle.

    “We excluded the discharges with interdischarge intervals < 33.3 or >250 ms because firing rates that calculated from this range of interdischarge intervals are unusually high (>30 Hz) or low (<4 Hz) for the VL muscle (7,20,21,30,31).”

The citation lists haven’t been fetched yet

References 45 · Cited by 219

Authors
Adam, A., & De Luca, C. J.
Affiliations
Boston University (US)
Venue
Journal of Applied Physiology
Published
2005-07
Volume
99
Issue
1
Pages
268-280
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2076436446
Cited by
219
References
45
Citations by year
2026: 4 · 2025: 11 · 2024: 15 · 2023: 15 · 2022: 11 · 2021: 9 · 2020: 13 · 2019: 12 · 2018: 11 · 2017: 13 · 2016: 18 · 2015: 15 · 2014: 8 · 2013: 9 · 2012: 6
FWCI
4.68
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Applied Physiology (publishedVersion)
  • PubMed (publishedVersion)
Funders
Eunice Kennedy Shriver National Institute of Child Health and Human Development (1R24 HD 38585, R24HD038585)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Muscle Physiology and Disorders
  • Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
Keywords
motor unit firing rate, vastus lateralis, muscle fatigue, isometric contraction, motor unit recruitment, motor unit action potentials, twitch potentiation
MeSH terms
Action Potentials, Adult, Electromyography, Physical Exertion, Humans, Isometric Contraction, Knee Joint, Male, Motor Neurons, Physical Endurance, Stress, Mechanical, Muscle, Skeletal, Muscle Fibers, Skeletal, Muscle Fatigue

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review