V̇o2 on-kinetics in isolated canine muscle in situ during slowed convective O2 delivery
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The purpose of this study was to examine O 2 uptake (V̇o 2) on-kinetics when the spontaneous blood flow (and therefore O 2 delivery) on-response was slowed by 25 and 50 s. The isolated gastrocnemius muscle complex (GS) in situ was studied in six anesthetized dogs during transitions from rest to a submaximal metabolic rate (≈50–70% of peak V̇o 2). Four trials were performed: 1) a pretrial in which resting and steady-state blood flows were established, 2) a control trial in which the blood flow on-kinetics mean response time (MRT) was set at 20 s (CT20), 3) an experimental trial in which the blood flow on-kinetics MRT was set at 45 s (EX45), and 4) an experimental trial in which the blood flow on-kinetics MRT was set at 70 s (EX70). Slowing O 2 delivery via slowing blood flow on-kinetics resulted in a linear slowing of the V̇o 2 on-kinetics response ( R = 0.96). Average MRT values for CT20, EX45, and EX70 V̇o 2 on-kinetics were (means ± SD) 17 ± 2, 23 ± 4, and 26 ± 3 s, respectively ( P < 0.05 among all). During these transitions, slowing blood flow resulted in greater muscle deoxygenation (as indicated by near-infrared spectroscopy), suggesting that lower intracellular Po 2 values were reached. In this oxidative muscle, V̇o 2 and O 2 delivery were closely matched during the transition period from rest to steady-state contractions. In conjunction with our previous work showing that speeding O 2 delivery did not alter V̇o 2 on-kinetics under similar conditions, it appears that spontaneously perfused skeletal muscle operates at the nexus of sufficient and insufficient O 2 delivery in the transition from rest to contractions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Skeletal muscle fatigue: cellular mechanisms
Allen, D. G., Lamb, G. D., & Westerblad, H. (2008) · Physiological Reviews · doi:10.1152/physrev.00015.2007 · Cited by 2,495
Maximal perfusion of skeletal muscle in man.
Andersen, P., & Saltin, B. (1985) · The Journal of Physiology · doi:10.1113/jphysiol.1985.sp015794 · Cited by 1,250
Muscle O2 uptake kinetics in humans: implications for metabolic control
Grassi, B., Poole, D. C., Richardson, R. S., Knight, D. R., Erickson, B. K., & Wagner, P. D. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.80.3.988 · Cited by 561
Grassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429
Oxygen Uptake Kinetics in Sport, Exercise and Medicine
Jones, A. M., & Poole, D. C. (2013) · doi:10.4324/9780203613771 · Cited by 342
Cited by
Grassi, B., & Quaresima, V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091313 · Cited by 345
“13,14 The main limitations of this approach can be summarized as follows: invasiveness of the measurements; technical problems inherently associated with in vivo blood flow measurements; the substantial impossibility (in human studies) to sample venous blood directly effluent from the exercising…”
BackgroundInfluentialvan der Zwaard, S., Jaspers, R. T., Blokland, I. J., Achterberg, C., Visser, J. M., den Uil, A. R., Hofmijster, M. J., Levels, K., Noordhof, D. A., de Haan, A., et al. (2016) · PLOS ONE · doi:10.1371/journal.pone.0162914 · Cited by 95
Koga, S., Barstow, T. J., Okushima, D., Rossiter, H. B., Kondo, N., Ohmae, E., & Poole, D. C. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01003.2014 · Cited by 60
Wüst, R. C. I., van der Laarse, W. J., & Rossiter, H. B. (2013) · The Journal of Physiology · doi:10.1113/jphysiol.2012.241992 · Cited by 44
SUN, Y., FERGUSON, B. S., ROGATZKI, M. J., MCDONALD, J. R., & GLADDEN, L. B. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001001 · Cited by 16
Self-citation
Metadata
- Authors
- Goodwin, M. L., Hernández, A., Lai, N., Cabrera, M. E., & Gladden, L. B.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2012-01-01
- Volume
- 112
- Issue
- 1
- Pages
- 9-19
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2317498803
- Cited by
- 31
- References
- 5
- FWCI
- 9.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: V̇o2 on-kinetics in isolated canine muscle in situ during slowed convective O2 delivery. https://app.cochat.ai/papers/10.1152/japplphysiol.01480.2010
- The paper
- Goodwin, M. L., Hernández, A., Lai, N., Cabrera, M. E., & Gladden, L. B. (2012). V̇o2 on-kinetics in isolated canine muscle in situ during slowed convective O2 delivery. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.01480.2010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.