The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A New Interpretation of Spontaneous Sway Measures Based on a Simple Model of Human Postural Control
Abstract
This study shows that center-of-pressure (COP) traces that closely resemble physiologically measured COP functions can be produced by an appropriate selection of model parameters in a simple feedback model of the human postural control system. Variations in the values of stiffness, damping, time delay, and noise level determine the values of 15 sway measures commonly used to characterize spontaneous sway. Results from model simulations indicate that there is a high degree of correlation among these sway measures, and the measures cluster into three different groups. Only two principal components accounted for about 92% of the variation among the different sway measures analyzed. This model can be used to formulate hypotheses regarding the cause of postural control deficits reported in the literature. This is accomplished using a multidimensional optimization procedure to estimate model parameters from a diverse set of spontaneous sway measures. These model parameters describe physiologically meaningful features of the postural control system as opposed to conventional sway measures that provide only a parametric description of sway. To show the application of this method, we applied it to published data of spontaneous sway from elderly subjects and contrasted it to the data of young healthy subjects. We found that modest increases in stiffness and damping and a fairly large increase in noise level with aging could account for the variety of sway measures reported in the literature for elderly subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feature selection of stabilometric parameters based on principal component analysis.
Rocchi, L., Chiari, L., & Cappello, A. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02351013 · Cited by 237
Cited by
ISway: a sensitive, valid and reliable measure of postural control
Mancini, M., Salarian, A., Carlson-Kuhta, P., Zampieri, C., King, L., Chiari, L., & Horak, F. B. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-59 · Cited by 499
The clinical utility of posturography
Visser, J. E., Carpenter, M. G., van der Kooij, H., & Bloem, B. R. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.07.220 · Cited by 490
Donker, S. F., Roerdink, M., Greven, A. J., & Beek, P. J. (2007) · Experimental Brain Research · doi:10.1007/s00221-007-0905-4 · Cited by 433
Multisensory control of human upright stance
Maurer, C., Mergner, T., & Peterka, R. J. (2006) · Experimental Brain Research · doi:10.1007/s00221-005-0256-y · Cited by 405
Self-citationQuijoux, F., Nicolaï, A., Chairi, I., Bargiotas, I., Ricard, D., Yelnik, A., Oudre, L., Bertin‐Hugault, F., Vidal, P., Vayatis, N., et al. (2021) · Physiological Reports · doi:10.14814/phy2.15067 · Cited by 349
Metadata
- Authors
- Maurer, C., & Peterka, R. J.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2005-01
- Volume
- 93
- Issue
- 1
- Pages
- 189-200
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2044494494
- Cited by
- 486
- References
- 1
- FWCI
- 38.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A New Interpretation of Spontaneous Sway Measures Based on a Simple Model of Human Postural Control. https://app.cochat.ai/papers/10.1152/jn.00221.2004
- The paper
- Maurer, C., & Peterka, R. J. (2005). A New Interpretation of Spontaneous Sway Measures Based on a Simple Model of Human Postural Control. Journal of Neurophysiology. https://doi.org/10.1152/jn.00221.2004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.