CoChat

Biophysical determinants of transcranial magnetic stimulation: effects of excitability and depth of targeted area

Open access
Stokes, Mark G., Barker, Anthony T., Dervinis, Martynas, Verbruggen, Frederick, Maizey, Leah, Adams, Rachel C., Chambers, Christopher D. · 2013 · Journal of Neurophysiology
Cited by 98

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Safe and effective transcranial magnetic stimulation (TMS) requires accurate intensity calibration. Output is typically calibrated to individual motor cortex excitability and applied to nonmotor brain areas, assuming that it captures a site nonspecific factor of excitability. We tested this assumption by correlating the effect of TMS at motor and visual cortex. In 30 participants, we measured motor threshold (MT) and phosphene threshold (PT) at the scalp surface and at coil-scalp distances of 3.17, 5.63, and 9.03 mm. We also modeled the effect of TMS in a simple head model to test the effect of distance. Four independent tests confirmed a significant correlation between PT and MT. We also found similar effects of distance in motor and visual areas, which did not correlate across participants. Computational modeling suggests that the relationship between the effect of distance and the induced electric field is effectively linear within the range of distances that have been explored empirically. We conclude that MT-guided calibration is valid for nonmotor brain areas if coil-cortex distance is taken into account. For standard figure-of-eight TMS coils connected to biphasic stimulators, the effect of cortical distance should be adjusted using a general correction factor of 2.7% stimulator output per millimeter.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.00510.2012

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 98

Metadata

Authors
Stokes, M. G., Barker, A. T., Dervinis, M., Verbruggen, F., Maizey, L., Adams, R. C., & Chambers, C. D.
Venue
Journal of Neurophysiology
Published
2013-01-15
Volume
109
Issue
2
Pages
437-444
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2072021499
Cited by
98
References
4
FWCI
1.97
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biophysical determinants of transcranial magnetic stimulation: effects of excitability and depth of targeted area. https://app.cochat.ai/papers/10.1152/jn.00510.2012
The paper
Stokes, M. G., Barker, A. T., Dervinis, M., Verbruggen, F., Maizey, L., Adams, R. C., & Chambers, C. D. (2013). Biophysical determinants of transcranial magnetic stimulation: effects of excitability and depth of targeted area. Journal of Neurophysiology. https://doi.org/10.1152/jn.00510.2012

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.