Cited by 64Neurological disorders and treatmentsMuscle activation and electromyography studiesMotor Control and Adaptation

Influence of common synaptic input to motor neurons on the neural drive to muscle in essential tremor

Open access
Gallego, Juan A., Dideriksen, Jakob L., Holobar, Ales, Ibáñez, Jaime, Pons, José L., Louis, Elan D., Rocon, Eduardo, Farina, Dario·2015·Journal of Neurophysiology

Abstract

Tremor in essential tremor (ET) is generated by pathological oscillations at 4–12 Hz, likely originating at cerebello-thalamo-cortical pathways. However, the way in which tremor is represented in the output of the spinal cord circuitries is largely unknown because of the difficulties in identifying the behavior of individual motor units from tremulous muscles. By using novel methods for the decomposition of multichannel surface EMG, we provide a systematic analysis of the discharge properties of motor units in nine ET patients, with concurrent recordings of EEG activity. This analysis allowed us to infer the contribution of common synaptic inputs to motor neurons in ET. Motor unit short-term synchronization was significantly greater in ET patients than in healthy subjects. Furthermore, the strong association between the degree of synchronization and the peak in coherence between motor unit spike trains at the tremor frequency indicated that the high synchronization levels were generated mainly by common synaptic inputs specifically at the tremor frequency. The coherence between EEG and motor unit spike trains demonstrated the presence of common cortical input to the motor neurons at the tremor frequency. Nonetheless, the strength of this input was uncorrelated to the net common synaptic input at the tremor frequency, suggesting a contribution of spinal afferents or secondary supraspinal pathways in projecting common input at the tremor frequency. These results provide the first systematic analysis of the neural drive to the muscle in ET and elucidate some of its characteristics that determine pathological tremulous muscle activity.

Integrity signals

Registry

Crossref · 10.1152/jn.00531.2014

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 59 · Cited by 64

Authors
Gallego, J. A., Dideriksen, J. L., Holobar, A., Ibáñez, J., Pons, J. L., Louis, E. D., Rocon, E., & Farina, D.
Affiliations
  • Neuroengineering and Cognitive Science Group, Centre for Automation and Robotics, Consejo Superior de Investigaciones Científicas, Arganda del Rey, Spain;
  • Bernstein Center for Computational Neuroscience Göttingen (DE)
  • Faculty of Electrical Engineering and Computer Science, University of Maribor, Maribor, Slovenia;
  • Consejo Superior de Investigaciones Científicas (ES)
  • Columbia University (US)
Corresponding author
Farina, Dario
Venue
Journal of Neurophysiology
Published
2015-01-01
Volume
113
Issue
1
Pages
182-191
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W1987649219
Cited by
64
References
59
Citations by year
2026: 1 · 2025: 1 · 2024: 3 · 2023: 8 · 2022: 14 · 2021: 4 · 2020: 8 · 2019: 6 · 2018: 7 · 2017: 1 · 2016: 5 · 2015: 4 · 2014: 1
FWCI
2.39
Type
journal article
Language
en
Open access
Licence
cc-by-nc-nd
Locations
  • Journal of Neurophysiology (publishedVersion)
  • PubMed (publishedVersion)
  • LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (acceptedVersion, cc-by-nc-nd)
  • Hispana (acceptedVersion, cc-by-nc-nd)
  • DIGITAL.CSIC (Spanish National Research Council (CSIC)) (submittedVersion, other-oa)
  • UCL Discovery (University College London) (submittedVersion)
  • Archivo Digital UPM (Universidad Politécnica de Madrid) (submittedVersion, cc-by-nc-nd)
  • GRO (submittedVersion)
Topics
  • Health Sciences › Medicine › Neurology › Neurological disorders and treatments
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
Keywords
essential tremor, common synaptic input, motor unit synchronization, motor unit spike trains, spinal cord circuitry, cerebello-thalamo-cortical pathway
MeSH terms
Action Potentials, Aged, Aged, 80 and over, Electroencephalography, Electromyography, Hand, Humans, Middle Aged, Motor Neurons, Synapses, Muscle, Skeletal, Essential Tremor, Sensorimotor Cortex

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review