The DOI matches its Crossref record.
Relative strength of synaptic input from short-latency pathways to motor units of defined type in cat medial gastrocnemius
Abstract
1. Intracellular recording and stimulation techniques were used in anesthetized cats to study the interrelations between amplitudes of PSPs produced by electrical stimulation of several short-latency pathways to MG alpha motoneurons and the mechanical properties of muscle units innervated by the same cells. Motor-unit types were identified by muscle-unit properties.2. The maximum amplitudes of monosynaptic EPSPs produced in MG motoneurons by activation of homonymous (MG) and heteronymous (LGS) group Ia afferents were clearly related to motor-unit type, being, on the average, largest in type S units, somewhat smaller in type FR and F(int) units, and smallest in type FF units. Correspondingly, group Ia EPSP amplitudes were inversely correlated with muscle-unit tension production and directly correlated with resistance to fatigue. The same input distribution was true for disynaptic IPSPs produced by group Ia afferents from antagonist ankle flexors.3. The amplitudes of monosynaptic EPSPs produced by fibers descending in the ipsilateral ventral funiculi of the low thoracic cord were not clearly related to MG motor-unit type or (therefore) to muscle-unit properties.4. A quantitative input-output model of the MG motor-unit pool, based in part on the present results, suggests that overall characteristics of MG motor units, and their relative numbers in the MG pool, reflect functional specializations determined by specific mechanical demands placed on the MG muscle by the usual motor behavior of the animal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Motor Units: Anatomy, Physiology, and Functional Organization
Burke, R. E. (1981) · Comprehensive Physiology · doi:10.1002/cphy.cp010210 · Cited by 782
Self-citationForces produced by medial gastrocnemius and soleus muscles during locomotion in freely moving cats.
Walmsley, B., Hodgson, J. A., & Burke, R. E. (1978) · Journal of Neurophysiology · doi:10.1152/jn.1978.41.5.1203 · Cited by 722
Self-citationMorin, C., Katz, R., Mazieres, L., & Pierrot-Deseilligny, E. (1982) · Neuroscience Letters · doi:10.1016/0304-3940(82)90128-8 · Cited by 254
On the function of muscle and reflex partitioning
Windhorst, U., Hamm, T. M., & Stuart, D. G. (1989) · Behavioral and Brain Sciences · doi:10.1017/s0140525x00024985 · Cited by 182
Factors causing difference in force output among motor units in the rat medial gastrocnemius muscle
Kanda, K., & Hashizume, K. (1992) · The Journal of Physiology · doi:10.1113/jphysiol.1992.sp019064 · Cited by 156
Metadata
- Authors
- Burke, R. E., & Rymer, W. Z.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 1976-05-01
- Volume
- 39
- Issue
- 3
- Pages
- 447-458
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W340302551
- Cited by
- 256
- References
- 0
- FWCI
- 10.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relative strength of synaptic input from short-latency pathways to motor units of defined type in cat medial gastrocnemius. https://app.cochat.ai/papers/10.1152/jn.1976.39.3.447
- The paper
- Burke, R. E., & Rymer, W. Z. (1976). Relative strength of synaptic input from short-latency pathways to motor units of defined type in cat medial gastrocnemius. Journal of Neurophysiology. https://doi.org/10.1152/jn.1976.39.3.447
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.