CoChat

Electrical measurement of axon diameter and its use in relating motoneuron size to critical firing level

Clamann, H. P., Henneman, E. · 1976 · Journal of Neurophysiology
Cited by 102

The DOI matches its Crossref record.

Abstract

1. Action potentials of single plantaris motoneurons were recorded monophasically from fine ventral root filaments. A resistor was placed in shunt across the recording electrodes and its value was varied until the size of the action potentials was reduced by one-half. At this point the resistance of the filament was taken to be equal to that of the shunt, and the quotient of action-potential amplitude divided by filament resistance was proportional to the axonal action current. 2. The measurement of axonal action currents depends on the assumption that the filament-electrode system obeys Ohm's law. Tests were performed which validated this assumption. It was then shown that the axonal action currents varied as the square of conduction velocity over the range of alpha and gamma motoneurons. 3. A direct correlation was established between the critical firing levels of motoneurons and the sizes of the impulses in their axons after the recorded sizes had been normalized in accordance with the resistances of the ventral root filaments in which they were located. Since both the CFL and axonal diameter were related to impulse size, they were related to each other (Fig. 6). 4. Evidence is cited justifying the conclusion that the dimater of a motor axon is directly related to the size of its soma. Thus, it may be inferred that the critical firing level of a motoneuron is a function of its size.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1976.39.4.844

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 102

Metadata

Authors
Clamann, H. P., & Henneman, E.
Venue
Journal of Neurophysiology
Published
1976-07-01
Volume
39
Issue
4
Pages
844-851
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2286570655
Cited by
102
References
0
FWCI
3.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrical measurement of axon diameter and its use in relating motoneuron size to critical firing level. https://app.cochat.ai/papers/10.1152/jn.1976.39.4.844
The paper
Clamann, H. P., & Henneman, E. (1976). Electrical measurement of axon diameter and its use in relating motoneuron size to critical firing level. Journal of Neurophysiology. https://doi.org/10.1152/jn.1976.39.4.844

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.