CoChat

Synaptic organization of defined motor-unit types in cat tibialis anterior

Dum, R. P., Kennedy, T. T. · 1980 · Journal of Neurophysiology
Cited by 46

The DOI matches its Crossref record.

Abstract

1. Synaptic potentials were recorded intracellularly in tibialis anterior (TA) motoneurons following stimulation of a descending brain stem pathway, the medial longitudinal fasciculus (MLF), and three segmental inputs, the homonymous and heteronymous group Ia afferents, the group I afferents from the antagonist, and the cutaneous and muscle afferents. Intracellular stimulation of the motoneurons was used to classify them, based on the properties of the innervated muscle units, into types FF, F(int), FR, and S (6, 16). 2. The sum of the monosynaptic EPSP amplitudes resulting from stimulation of homonymous and heteronymous group Ia afferents (summed group Ia EPSP) was inversely related to motoneuron size, as assessed by motoneuron input resistance, and was inversely related to motor-unit tetanic tension. Type-FF, -FR, and -S motoneurons showed significant differences in the mean amplitude of their summed group Ia EPSPs. 3. The amplitudes of disynaptic IPSPs resulting from stimulation of group I afferents in the antagonist muscle also showed an inverse relationship to motoneuron size. The observed relationships between motoneuron size and the monosynaptic group Ia EPSP amplitude or the disynaptic group I IPSP amplitude are compatible with the “size principle” of motor-unit recruitment (26). 4. The amplitudes of the monosynaptic EPSPs evoked in TA motoneurons by stimulation of the MLF were distributed rather randomly among all types of TA motoneurons. A slight tendency of larger monosynaptic EPSPs to occur in motoneurons with larger tetanic tensions was observed. 5. The polysynaptic effects from cutaneous and muscle afferents in sural and gastrocnemius-soleus nerves were frequently excitatory on type-FF motoneurons, but were primarily inhibitory on type-FR and -S motoneurons. Clearly, the polysynaptic cutaneous and muscle inputs and the monosynaptic MLF input onto TA motoneurons show a different pattern of synaptic organization than the group I inputs. 6. In general, the synaptic organization of the TA motor nucleus is similar to that of its extensor antagonist, medial gastrocnemius (MG) (2--5, 7, 8), when analogous neural circuits are compared. This parallel organization suggests a commonality of motor-control systems for both flexor and extensor muscles.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1980.43.6.1631

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 46

Metadata

Authors
Dum, R. P., & Kennedy, T. T.
Venue
Journal of Neurophysiology
Published
1980-06-01
Volume
43
Issue
6
Pages
1631-1644
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2262653011
Cited by
46
References
0
FWCI
1.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Synaptic organization of defined motor-unit types in cat tibialis anterior. https://app.cochat.ai/papers/10.1152/jn.1980.43.6.1631
The paper
Dum, R. P., & Kennedy, T. T. (1980). Synaptic organization of defined motor-unit types in cat tibialis anterior. Journal of Neurophysiology. https://doi.org/10.1152/jn.1980.43.6.1631

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.