Abstract

The action spike activities of single ganglion cells were recorded from the nasal retina of the intact eye of anesthetized and immobilized cats. Each ganglion cell was identified as a Y-, X-, or W-cell on the basis of its axonal conduction velocity, its receptive-field properties, and the level of maintained activity. Of about 100 ganglion cells physiologically identified and penetrated with horseradish peroxidase (HRP)-containing glass microelectrodes, 21 cells were subsequently identified in flat-mount preparations of the retinas and processed for detection of HRP. Of a total of nine Y-cells recovered, four had been penetrated at the soma and five at the axon. All had the morphology of the alpha-cell of Boycott and Wassle. Eight X-cells recovered. All had been penetrated at the soma and showed beta-cell morphology. Four W-cells were penetrated at the soma and recovered. Two off-tonic W-cells had small somas (15-16 micron in diam) and sparse dendritic fields, resembling gamma-cells of Boycott and Wassle. They are also similar to “G4” and “G18” of Kolb et al.'s classification. One on-tonic W-cell had somewhat larger soma (18 micron) with a relatively densely branched dendritic field. This corresponds to delta-cell of Boycott and Wassle or to “G15” of Kolb et al. One on-off phasic W-cell had a medium-sized soma (25.3 micron) with a fanlike dendritic expansion characteristic of the “unilateral horizontal broad range cell” of Shkolnik-Yarros or of “G22” of Kolb et al. Alternatively, all these W-cells can be called medium-sized gamma-cells. Among all three classes of ganglion cells, a positive correlation was found between the diameter of the receptive-field center and the dendritic field. Assuming that in the cat retina 1 degree of visual angle = 230 micron, dendritic fields of Y-cells seemed larger than their physiologically determined receptive-field centers. By contrast, the reverse relation was found between these two dimensions in X-cells. Axon diameters ranged from 4.0 to 5.6 micron (mean, 4.5 micron) in Y-cells and from 1.9 to 2.7 micron (mean, 2.2 micron) in X-cells. Three W-cells showed axon diameters of 0.6, 1.1, and 1.8 micron. The axon diameter distributions made from axons labeled by massive injections of HRP into the optic nerve fiber layer showed a pattern of distribution similar to that obtained from physiologically identified Y-, X-, and W-cell axons.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1984.52.6.999

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 141

Metadata

Authors
Fukuda, Y., Hsiao, C. F., Watanabe, M., & Ito, H.
Venue
Journal of Neurophysiology
Published
1984-12-01
Volume
52
Issue
6
Pages
999-1013
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2410000813
Cited by
141
References
0
FWCI
4.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Morphological correlates of physiologically identified Y-, X-, and W-cells in cat retina. https://app.cochat.ai/papers/10.1152/jn.1984.52.6.999
The paper
Fukuda, Y., Hsiao, C. F., Watanabe, M., & Ito, H. (1984). Morphological correlates of physiologically identified Y-, X-, and W-cells in cat retina. Journal of Neurophysiology. https://doi.org/10.1152/jn.1984.52.6.999

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.