Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 236

The DOI matches its Crossref record.

Relationship among recruitment order, axonal conduction velocity, and muscle-unit properties of type-identified motor units in cat plantaris muscle

Zajac, F. E., Faden, J. S. · 1985 · Journal of Neurophysiology

Abstract

A strict interpretation of the size-principle hypothesis (37, 39-41) is that a muscle's motor units should be recruited in an ascending order according to both the size of their motoneurons and the size of their innervated muscle units (for reviews see Refs. 9, 39, 73). Studies of large mixed muscles in the cat hindlimb, however, have shown that motor axonal conduction velocity and tetanic tension, which are frequently considered indices of motoneuron and muscle-unit size, respectively, are uncorrelated in the fast-twitch (type F) motor-unit subpopulation (12, 13, 23, 24, 30, 32, 63, 71, 79). Attempting to focus on type F units, we compared the recruitment order of 42 pairs of cat plantaris (PL) motor units with both axonal conduction velocity and tetanic tension as well as with other muscle-unit properties. Single PL alpha-motor axons were functionally isolated in intact L7 ventral root filaments of decerebrate cats. Tension responses produced by stimulating each isolated motor axon were used to find the tetanic tension of the muscle unit and to classify the unit (12) as either type S (slow twitch, fatigue resistant), type FR (fast twitch, fatigue resistant), type FI (fast twitch, intermediate fatigability), or type FF (fast twitch, highly fatigable). Conduction velocity of each isolated axon was computed from measurements of axonal conduction time and length. The axon's reflex discharges were recorded from the proximal end of the cut filament and compared with the discharges of another PL axon residing in a different, previously cut filament of the same cat. The recruitment order of each motor-unit pair studied was found during reflexes elicited by homonymous muscle stretch, tendon taps, or single shocks at group I intensity to the PL nerve. If either axon of the pair failed to discharge, as often was the case with the high-threshold type F units, the monosynaptic reflex was facilitated by a 500-pps conditioning train applied proximal to a complete reversible cooling block of the PL nerve. In all 42 pairs studied, the weaker motor unit had the lower functional threshold for recruitment. Recruitment also invariably followed the order S greater than FR greater than FI greater than FF units. The motor unit of a pair with the higher resistance to fatigue thus always had the lower functional threshold. In 21 of the 22 pairs containing at least one type S motor unit, the unit with the slower-conducting motor axon had the lower functional threshold for recruitment.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1985.53.5.1303

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 236

Metadata

Authors
Zajac, F. E., & Faden, J. S.
Venue
Journal of Neurophysiology
Published
1985-05-01
Volume
53
Issue
5
Pages
1303-1322
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W1883428669
Cited by
236
References
0
FWCI
5.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Relationship among recruitment order, axonal conduction velocity, and muscle-unit properties of type-identified motor units in cat plantaris muscle. https://app.cochat.ai/papers/10.1152/jn.1985.53.5.1303
The paper
Zajac, F. E., & Faden, J. S. (1985). Relationship among recruitment order, axonal conduction velocity, and muscle-unit properties of type-identified motor units in cat plantaris muscle. Journal of Neurophysiology. https://doi.org/10.1152/jn.1985.53.5.1303

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.