The DOI matches its Crossref record.
Spatial and temporal response properties of the vestibulocollic reflex in decerebrate cats
Abstract
Vestibulocollic reflex responses of several neck muscles in decerebrate cats were studied during angular rotations of the whole body in a large number of vertical and horizontal rotation planes, at frequencies from 0.07 to 1.6 Hz. Vestibulocollic responses were compared to eye muscle and forelimb muscle vestibular responses. Electromyographic activity was recorded by fine wires inserted in biventer cervicis, complexus, longus capitis, obliquus capitis inferior, occipitoscapularis, rectus capitis major, splenius, lateral rectus, and triceps brachii. At frequencies of approximately 0.5 Hz and above, neck muscle electromyographic response gains were sinusoidal functions of stimulus orientation within a set of vertical or horizontal planes, and a muscle's response phase remained constant across rotation planes, or reversed by 180 degrees. Response patterns at high frequencies were consistent with vestibulocollic reflex activation by semicircular canals through brain circuitry that modifies canal dynamics. At frequencies of approximately 0.5 Hz and above, the stimulus orientation in which a given neck muscle's response was maximal remained nearly constant across frequencies. Thus, we used responses to rotations at high frequencies to calculate axes of maximal response of each muscle in three-dimensional space. Lateral rectus, obliquus, and to a lesser extent, splenius and longus capitus were activated predominantly by horizontal rotations. Biventer was activated predominantly by pitch, triceps predominantly by roll, and complexus, occipitoscapularis, and rectus major significantly excited by rotations in all three coordinate planes. In some cases, at frequencies less than 0.5 Hz, neck muscle response phase varied depending on the vertical plane in which the cat was rotated, and the optimal response plane was poorly defined and varied with frequency. These responses indicated that, at some frequencies, neck muscle activity can result from summation of inputs with differing spatial orientation and dynamics (spatial-temporal convergence). Differences between responses to vertical and horizontal rotations suggested that low-frequency spatial-temporal convergence behavior of the vestibulocollic reflex during vertical rotations was due to convergent semicircular canal and otolith receptor inputs.(ABSTRACT TRUNCATED AT 400 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Visual, vestibular and voluntary contributions to human head stabilization
Guitton, D., Kearney, R. E., Wereley, N., & Peterson, B. W. (1986) · Experimental Brain Research · doi:10.1007/bf00238201 · Cited by 296
Self-citationLackner, J. R., & DiZio, P. (1992) · The Head-Neck Sensory Motor System · doi:10.1093/acprof:oso/9780195068207.003.0033 · Cited by 11
Metadata
- Authors
- Baker, J., Goldberg, J., & Peterson, B.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 1985-09-01
- Volume
- 54
- Issue
- 3
- Pages
- 735-756
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2410881128
- Cited by
- 225
- References
- 0
- FWCI
- 4.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spatial and temporal response properties of the vestibulocollic reflex in decerebrate cats. https://app.cochat.ai/papers/10.1152/jn.1985.54.3.735
- The paper
- Baker, J., Goldberg, J., & Peterson, B. (1985). Spatial and temporal response properties of the vestibulocollic reflex in decerebrate cats. Journal of Neurophysiology. https://doi.org/10.1152/jn.1985.54.3.735
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.