Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 225

The DOI matches its Crossref record.

Spatial and temporal response properties of the vestibulocollic reflex in decerebrate cats

Baker, J., Goldberg, J., Peterson, B.·1985·Journal of Neurophysiology

Abstract

Vestibulocollic reflex responses of several neck muscles in decerebrate cats were studied during angular rotations of the whole body in a large number of vertical and horizontal rotation planes, at frequencies from 0.07 to 1.6 Hz. Vestibulocollic responses were compared to eye muscle and forelimb muscle vestibular responses. Electromyographic activity was recorded by fine wires inserted in biventer cervicis, complexus, longus capitis, obliquus capitis inferior, occipitoscapularis, rectus capitis major, splenius, lateral rectus, and triceps brachii. At frequencies of approximately 0.5 Hz and above, neck muscle electromyographic response gains were sinusoidal functions of stimulus orientation within a set of vertical or horizontal planes, and a muscle's response phase remained constant across rotation planes, or reversed by 180 degrees. Response patterns at high frequencies were consistent with vestibulocollic reflex activation by semicircular canals through brain circuitry that modifies canal dynamics. At frequencies of approximately 0.5 Hz and above, the stimulus orientation in which a given neck muscle's response was maximal remained nearly constant across frequencies. Thus, we used responses to rotations at high frequencies to calculate axes of maximal response of each muscle in three-dimensional space. Lateral rectus, obliquus, and to a lesser extent, splenius and longus capitus were activated predominantly by horizontal rotations. Biventer was activated predominantly by pitch, triceps predominantly by roll, and complexus, occipitoscapularis, and rectus major significantly excited by rotations in all three coordinate planes. In some cases, at frequencies less than 0.5 Hz, neck muscle response phase varied depending on the vertical plane in which the cat was rotated, and the optimal response plane was poorly defined and varied with frequency. These responses indicated that, at some frequencies, neck muscle activity can result from summation of inputs with differing spatial orientation and dynamics (spatial-temporal convergence). Differences between responses to vertical and horizontal rotations suggested that low-frequency spatial-temporal convergence behavior of the vestibulocollic reflex during vertical rotations was due to convergent semicircular canal and otolith receptor inputs.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1985.54.3.735

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 225

Metadata

Authors
Baker, J., Goldberg, J., & Peterson, B.
Venue
Journal of Neurophysiology
Published
1985-09-01
Volume
54
Issue
3
Pages
735-756
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2410881128
Cited by
225
References
0
FWCI
4.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Spatial and temporal response properties of the vestibulocollic reflex in decerebrate cats. https://app.cochat.ai/papers/10.1152/jn.1985.54.3.735
The paper
Baker, J., Goldberg, J., & Peterson, B. (1985). Spatial and temporal response properties of the vestibulocollic reflex in decerebrate cats. Journal of Neurophysiology. https://doi.org/10.1152/jn.1985.54.3.735

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.