Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 209

The DOI matches its Crossref record.

Reflex and mechanical contributions to head stabilization in alert cats

Goldberg, J., Peterson, B. W.·1986·Journal of Neurophysiology

Abstract

Five alert cats were tested for their responses to rotation in a device that allowed rotation of the head on the trunk about a vertical axis passing through the C1-C2 vertebral joint. Electrodes were implanted to record the horizontal and vertical electrooculogram and electromyographic (EMG) activity of the dorsal neck muscles splenius, biventer cervicus, and complexus. Head rotation and torque acting on the head were recorded in the horizontal plane during rotations in the 0.05-5.0 Hz frequency range. Responses were interpreted with reference to a closed-loop dynamic model of the head-neck system. Whole-body rotation (WBR) with no neck movement elicited a vestibulocollic reflex (VCR). Neck muscle EMG lagged the sinusoidal platform rotation by approximately 120 degrees at low frequencies, which represents a 60 degrees lead relative to a perfectly compensatory 180 degrees lag. This phase lead was related to the cumulative eye position of the accompanying horizontal vestibular nystagmus as reported by Vidal et al. Horizontal head torque exhibited a similar low-frequency behavior. At high frequencies, EMG exhibited a progressively increasing phase lead and gain increase typical of a second-order lead system as described in decerebrate cats. Torque, however, showed much less lead and gain increase, presumably because of the low-pass filter properties of the process coupling muscle excitation to torque. Head torque did exhibit a steep increase in gain with frequency and a phase approaching that of platform acceleration at high frequencies when weights were attached to the head to increase its moment of inertia. The same +40 dB/decade gain slope and phase approaching 0 degree was observed during WBR rotation of the anesthetized cat in which head inertia is the only factor contributing to the torque. This dynamic behavior was predicted by the inertial component of the model. In the alert unweighted cat, the inertial torque was smaller than VCR-generated torque at frequencies below 4 Hz. Rotation of the neck with the head held fixed in space (HFS rotation) elicited a cervicocollic reflex (CCR). Neck EMG response was very similar to that observed during WBR, both in dynamic behavior and overall gain. Torque, however, was consistently greater than that generated by WBR and showed a steady increase of 8 dB/decade as frequency rose. The added torque can be attributed to the viscoelastic properties of neck muscles. Driven rotation of the head on the fixed body elicited torques that could be closely approximated by a vector sum of torques observed during WBR and HFS rotations.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1986.56.3.857

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 209

Metadata

Authors
Goldberg, J., & Peterson, B. W.
Venue
Journal of Neurophysiology
Published
1986-09-01
Volume
56
Issue
3
Pages
857-875
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2204195862
Cited by
209
References
0
FWCI
1.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reflex and mechanical contributions to head stabilization in alert cats. https://app.cochat.ai/papers/10.1152/jn.1986.56.3.857
The paper
Goldberg, J., & Peterson, B. W. (1986). Reflex and mechanical contributions to head stabilization in alert cats. Journal of Neurophysiology. https://doi.org/10.1152/jn.1986.56.3.857

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.