CoChat

Stimulus-response function studies of esophageal mechanosensitive nociceptors in sympathetic afferents of opossum

Sengupta, J. N., Saha, J. K., Goyal, R. K. · 1990 · Journal of Neurophysiology
Cited by 155

The DOI matches its Crossref record.

Abstract

1. Single-unit activity was recorded from afferent fibers in either the paravertebral sympathetic chain or the splanchnic nerves. Forty-three fibers that responded to distension of the smooth-muscle portion of esophagus were selected for further study. 2. Out of the 43 fibers, 27 (62%) had ongoing resting activity, and 16 (38%) were silent. The mean resting activity of these fibers was 0.28 +/- 0.06 imp/s (range, 0-2.6 imp/s). 3. Repeated distensions of the esophagus to a fixed pressure (80 mmHg) evoked spike discharge at a reproducible rate. There was no evidence of facilitation or inhibition of subsequent responses. The mean coefficient of variation (CV) was 0.17 +/- 0.05 imp/s (n = 5). 4. The stimulus-response function (SRF) to intraluminal graded distension was studied in 35 fibers. Thirty-three fibers showed linear increase in firing that did not saturate up to 120 mmHg. Two fibers reached maximal discharge rate at 60 mmHg. The mean discharge rate at 120 mmHg pressure was 14.87 +/- 1.52 imp/s. 5. Threshold pressure for activation of each fiber was calculated by a least-squares linear-regression plot of the SRF. The threshold pressure varied from 0 to 50 mmHg (mean, 16.21 +/- 2.86 mmHg). The distribution profile of the threshold values showed that there were two separate populations of mechanosensitive receptors: 1) wide-dynamic-range mechanonociceptors (WDR-MN) with mean threshold pressure of 2.89 +/- 0.75 mmHg (range, 0-7 mmHg; n = 22); and 2) high-threshold mechanonociceptors (HT-MN) with mean threshold of 33.26 +/- 2.52 mmHg (range, 19-50 mmHg; n = 13). 6. Discharge evoked by esophageal peristalsis was studied in five WDR-MN and five HT-MN units. Whereas all five WDR-MN units (threshold value, 2.6 +/- 0.96 mmHg) responded to peristalsis, none of the HT-MN units (threshold value, 31.2 +/- 4.01 mmHg) did so. The mean response to peristaltic contraction in WDR-MN units was 5.32 +/- 1.36 imp/s, which was 24.7% of the maximal response (21.53 +/- 1.92 imp/s; n = 5) at 120 mmHg. The duration of evoked response to peristaltic contraction was 10-12 s. 7. The activity profile of the units to 60-s balloon distension at near threshold and higher pressures showed three patterns: 1) rapid adaptation, 2) slow adaptation, and 3) slow adaptation with after discharge. The rapidly adapting fibers became slowly adapting with greater degrees of esophageal distension. The units that showed rapid or slow adaptation at low-distension pressure became indistinguishable from one another at high-distension pressure.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1990.64.3.796

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 155

Metadata

Authors
Sengupta, J. N., Saha, J. K., & Goyal, R. K.
Venue
Journal of Neurophysiology
Published
1990-09-01
Volume
64
Issue
3
Pages
796-812
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W173988102
Cited by
155
References
0
FWCI
4.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stimulus-response function studies of esophageal mechanosensitive nociceptors in sympathetic afferents of opossum. https://app.cochat.ai/papers/10.1152/jn.1990.64.3.796
The paper
Sengupta, J. N., Saha, J. K., & Goyal, R. K. (1990). Stimulus-response function studies of esophageal mechanosensitive nociceptors in sympathetic afferents of opossum. Journal of Neurophysiology. https://doi.org/10.1152/jn.1990.64.3.796

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.