Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 188

The DOI matches its Crossref record.

Contrasting properties of monkey somatosensory and motor cortex neurons activated during the control of force in precision grip

Wannier, T. M., Maier, M. A., Hepp-Reymond, M. C. · 1991 · Journal of Neurophysiology

Abstract

1. Single cell activity was investigated in the precentral motor (MI) and postcentral somatosensory (SI) cortex of the monkey to compare the neuronal activity related to the control of isometric force in the precision grip and to assess the participation of SI in motor control. 2. Three monkeys (Macaca fascicularis) were trained in a visual step-tracking paradigm to generate and precisely maintain force on a transducer held between thumb and index finger. Great care was taken to have the monkeys use only their fingers without moving the wrist or proximal joints. In two monkeys electromyographic (EMG) activity was checked in 23 muscles over several sessions. 3. Five similar classes of task-related firing patterns were found in both SI and MI cortical hand and finger representations, but their relative proportions differed. The majority of the SI neurons were phasically or phasic-tonically active (61%), whereas in MI the neurons that decreased their firing rate with force were most frequent (42%). 4. The timing of activity changes related to the onset of force increase from low to higher levels strongly differed in the two neuronal populations. In SI, only 14% of the task-related neurons increased or decreased their firing rate before the onset of force increase, in contrast to 56% in MI. Only 3% of the SI neurons showed changes before the earliest EMG activation. 5. In both SI and MI neurons with tonic and phasic-tonic, increasing or decreasing discharge patterns disclosed a relationship between neuronal activity and static force. Distinction was made between neurons modulating their activity in a monotonic way and those that were active only at one force level and had a kind of recruitment or deactivation threshold. The latter ones were more frequent in MI than in SI, and in the neuron population with decreasing firing patterns. For the neurons with increases in activity, statistically significant linear correlations between firing rate and force were found more frequently in MI than in SI, where the proportion of nonsignificant correlations was relatively high (35% vs. 15% in MI). In SI the indexes of force sensitivity, calculated from the slopes of the regression lines, covered a wider range than in MI; and their distribution was bimodal, with one mean of 30 Hz/N and the other of 155 Hz/N. In contrast, the mean rate-force slope in MI was 69 Hz/N.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1991.65.3.572

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 188

Metadata

Authors
Wannier, T. M., Maier, M. A., & Hepp-Reymond, M. C.
Venue
Journal of Neurophysiology
Published
1991-03-01
Volume
65
Issue
3
Pages
572-589
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2179805876
Cited by
188
References
0
FWCI
15.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Contrasting properties of monkey somatosensory and motor cortex neurons activated during the control of force in precision grip. https://app.cochat.ai/papers/10.1152/jn.1991.65.3.572
The paper
Wannier, T. M., Maier, M. A., & Hepp-Reymond, M. C. (1991). Contrasting properties of monkey somatosensory and motor cortex neurons activated during the control of force in precision grip. Journal of Neurophysiology. https://doi.org/10.1152/jn.1991.65.3.572

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.