Finger movement responses of cutaneous mechanoreceptors in the dorsal skin of the human hand
Abstract
1. The movement sensitivity of dorsal skin mechanoreceptors in the human hand was studied by the use of single afferent recording techniques. 2. Units were classified as slowly (SA) and fast adapting (FA) and further characterized by thresholds to vertical indentation and by receptive-field sizes. Whereas SA units were evenly distributed within the supply area of the superficial branch of the radial nerve. FA units were usually situated near joints. 3. The proportion of different receptor types (32% SAI, 32% SAII, 28% FAI, 8% FAII; n = 107) compared favorably with previous electrophysiological and anatomic data, arguing for minimal sampling bias. The majority of the skin mechanoreceptive units were SA, largely due to a relative scarcity of FAII [Pacinian corpuscles (PC)] units. 4. A large majority (92%) of the afferents responded to active hand or finger movements. Responses in all unit types were consistent with observed movement-induced deformations of their receptive fields. 5. FAI units responded bidirectionally, albeit usually with somewhat higher discharge frequencies for finger flexion, which in most cases were associated with skin stretch. FAI units showed meager responses to remote stimuli, typically responding to one or, at the most, two adjacent joints. 6. SA units typically showed simple directional responses to joint movements with an increased discharge during flexion and a reduced discharge during extension. Joint movement that influenced the skin within the receptive field of SA units elicited graded responses even if the field, as assessed by perpendicular indentations, was minute. This finding suggests that definition of cutaneous receptive fields by classical perpendicular indentations may be inappropriate for the receptors in the hairy, nonglabrous skin. 7. The interpretation of the data from these recordings suggests that cutaneous mechanoreceptors in the dorsal skin can provide the CNS with detailed kinematic information, at least for movements of the hand.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
For the hand dorsum and arm, we found a total of 267 reported afferents in the literature, 61% of which were slowly adapting.
“For the hand dorsum and arm, we found a total of 267 reported afferents in the literature, 61% of which were slowly adapting (Ackerley et al. 2014;Edin and Abbs 1991;Edin et al. 1995;Kakuda 1992;Lo ¨ken et al. 2009;Nagi et al. 2019;Vallbo et al. 1995).”
From Tactile innervation densities across the whole body (2020) · cites this paper as Edin and Abbs 1991
The citation lists haven’t been fetched yet
Cited by 358
- Authors
- Edin, B. B., & Abbs, J. H.
- Affiliations
- University of Wisconsin–Madison (US)
- ORCID
- Edin, B. B.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 1991-03-01
- Volume
- 65
- Issue
- 3
- Pages
- 657-670
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W1962219533
- Cited by
- 358
- References
- 0
- Citations by year
- 2026: 5 · 2025: 5 · 2024: 9 · 2023: 8 · 2022: 14 · 2021: 14 · 2020: 11 · 2019: 6 · 2018: 12 · 2017: 7 · 2016: 17 · 2015: 9 · 2014: 11 · 2013: 9 · 2012: 17
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Neurophysiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5p01ns013274-11)
- National Institute of Neurological Disorders and Stroke (NS-13274)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Life Sciences › Neuroscience › Sensory Systems › Ion Channels and Receptors
- Keywords
- cutaneous mechanoreceptors, finger movement, slowly adapting receptors, Pacinian corpuscles, receptive fields, skin stretching, joint movement, hand kinematics, afferent discharge
- MeSH terms
- Adaptation, Physiological, Adolescent, Adult, Electric Stimulation, Female, Fingers, Hand, Humans, Male, Mechanoreceptors, Movement, Neurons, Afferent, Skin, Signal Transduction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review