Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 168

The DOI matches its Crossref record.

Neural interaction in cat primary auditory cortex. Dependence on recording depth, electrode separation, and age

Eggermont, J. J.·1992·Journal of Neurophysiology

Abstract

1. Neural activity was recorded with two independent electrodes separated by 0.5-2 mm, aligned in parallel, and advanced perpendicular to the surface of the cat auditory cortex. For smaller separations a solid-state multielectrode array with interelectrode distances of 125 microns was used. The difference in recording depths for the two independently movable electrodes was never more than 100 microns; the electrode contacts of the multielectrode array were at the same depth. Thus the correlation studies dominantly explored horizontal interactions. 2. Out of 995 neuron pairs recorded, 478 represented pairs of single units, whereas the other pairs were contaminated with 5-10% misclassified spikes. Only the single-unit pairs were further analyzed. Of those pairs, 338 showed a clear correlation peak, and in 329 of these the peak heights were exceeding the Z > 4 significance level (P < 0.0001). Two hundred fifty-two of the significant correlograms (53% of total) could be attributed to common input; the remaining (16% of total) were indicative of unilateral excitation. For the 181 single-electrode pairs the percentage of unilateral excitation pairs (42%) was about the same as the percentage of common input pairs (38%). For the 297 dual-electrode pairs all but one of the 184 significant correlations were indicative of common input. No correlograms indicative of inhibition were found. 3. The correlograms with clear peaks were classified into three types: narrow (n = 40), mixed (n = 77), and broad (n = 221). Narrow and mixed types were with two exceptions found only for single-electrode pairs; broad types were found for single- and dual-electrode pairs. Narrow-type correlograms were in majority of the unilateral excitation type. Correlograms were calculated both for 1-ms binwidths (50-ms lead/lag time) and for 10-ms binwidth (500-ms lead/lag time). The correlograms were characterized by four parameters; the half width of the central peak, the peak correlation coefficient, the association index, and for unilateral excitation cases also by the effectiveness. 4. Across all three correlogram types the half width of the correlation peaks was significantly smaller for single-electrode pairs (mean, 27 ms) than for dual-electrode pairs (mean, 42 ms). For broad-type correlograms only, the mean half widths were not significantly different between single- and dual-electrode pairs. 5. The correlation coefficients (1-ms bin correlograms) were significantly larger for single-electrode pairs (mean, 0.038) than for dual-electrode pairs (mean, 0.011). The same was found for the 10-ms binwidth correlograms.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1992.68.4.1216

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 168

Metadata

Authors
Eggermont, J. J.
Venue
Journal of Neurophysiology
Published
1992-10-01
Volume
68
Issue
4
Pages
1216-1228
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2269952648
Cited by
168
References
0
FWCI
1.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Neural interaction in cat primary auditory cortex. Dependence on recording depth, electrode separation, and age. https://app.cochat.ai/papers/10.1152/jn.1992.68.4.1216
The paper
Eggermont, J. J. (1992). Neural interaction in cat primary auditory cortex. Dependence on recording depth, electrode separation, and age. Journal of Neurophysiology. https://doi.org/10.1152/jn.1992.68.4.1216

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.