CoChat

Antidromic responses of single units from the spiral ganglion

Brown, M. C. · 1994 · Journal of Neurophysiology
Cited by 68

The DOI matches its Crossref record.

Abstract

1. Antidromic responses of single units in the guinea pig spiral ganglion were recorded in response to shocks to the auditory nerve root. The orthodromic responses of these units were also recorded in response to sound. The aim of this study was 1) to classify units according to their response patterns to shocks and to sound and 2) to propose anatomic types that might correlate with these responses. The four classes of units were as follows: type I, olivocochlear (OC), long-latency: locked, and long-latency: jittering. 2. Type I units responded antidromically to shocks with little jitter and short latency. Their responses to sound were also of short latency and had irregular interspike intervals. Some of these units had complex spike waveforms. These units likely correspond to type I primary afferent neurons, the majority population of spiral ganglion cells. 3. One-third of the OC units responded to shocks, with little jitter and intermediate latency (2 ms). OC unit responses to sound were of long latency and had regular interspike intervals. These units likely correspond to efferent neurons that originate in the superior olivary complex of the brain and end on outer hair cells in the cochlea. 4. Long-latency: locked units responded to shocks with little jitter and long latency (4–11 ms). Many of these units had complex spike waveforms and most did not respond to high-level noise bursts. Long-latency: locked units may correspond to type II spiral ganglion neurons. 5. Long-latency: jittering units responded to shocks with a jitter of several milliseconds and long latency. Some of these units responded to sound in a pattern reminiscent of OC units. These units may constitute a subgroup of OC units that respond to shocks via activation of the reflex pathway from the cochlea to the superior olive and back out to the cochlea. 6. Further data were collected on the type I response to shocks. Antidromic spikes lacked the inflections seen on the waveforms that are typically seen on orthodromic spikes. Type I shock responses depended on shock level and duration and were reduced when a click preceded the shock by approximately 2 ms. Several type I characteristics depended on the rate of spontaneous discharge: for units of low and medium spontaneous rates (when compared with units of high rates), the shock thresholds were lower, shock latencies were longer, and the probability of firing repetitive spikes to a single shock was higher.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1994.71.5.1835

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 68

Metadata

Authors
Brown, M. C.
Venue
Journal of Neurophysiology
Published
1994-05-01
Volume
71
Issue
5
Pages
1835-1847
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W1765574357
Cited by
68
References
0
FWCI
1.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Antidromic responses of single units from the spiral ganglion. https://app.cochat.ai/papers/10.1152/jn.1994.71.5.1835
The paper
Brown, M. C. (1994). Antidromic responses of single units from the spiral ganglion. Journal of Neurophysiology. https://doi.org/10.1152/jn.1994.71.5.1835

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.