The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Spike-frequency adaptation studied in hypoglossal motoneurons of the rat
Abstract
1. We studied spike frequency adaptation of motoneuron discharge in the rat hypoglossal nucleus using a brain stem slice preparation. The characteristics of adaptation in response to long (60 s) injected current steps were qualitatively similar to those observed previously in cat hindlimb motoneurons. The discharge rate typically exhibited a rapid initial decline, characterized by a linear frequency-time relation, followed by a gradual exponential decline that continued for the duration of current injection. However, a more systematic, quantitative analysis of the data revealed that there were often three distinct phases of the adaptation rather than two. 2. The three phases of adaptation (initial, early, and late) were present in at least one 60-s trial of repetitive firing in all but a small number of motoneurons. Initial adaptation was limited to the first few spikes except in a few trials (7%) in which there was no initial adaptation. The time course of the subsequent decline in rate could be adequately described by a single-exponential function in about half of the trials (48%). In the remaining trials this subsequent decline in frequency was better described as the sum of two exponential functions: an early phase, lasting < 2 s, and a late phase, which lasted for the duration of the discharge period. 3. The magnitude of initial adaptation was correlated with the initial firing frequency (i.e., the reciprocal of the 1st interspike interval). The magnitudes of the early and late phases of adaptation were correlated with the firing frequency reached at the end of initial adaptation. Neither the magnitudes nor the time courses of the three phases were correlated with other membrane properties such as input resistance, rheobase, or repetitive firing threshold. 4. The slope of the frequency-current (f-I) curve was steeper in the initial phase (first 2-5 spikes) than in either the early (< 2 s) or late (> 2 s) phases of adaptation as previously reported by other investigators. In the absence of early adaptation, a steady state for the f-I slope was reached by 0.7-1 s, the time typically reported in studies of repetitive discharge. However, when early adaptation was present (50% of the trials), a steady-state value for the f-I slope was not reached until the cell had discharged for > 1 s. 5. To characterize the time course of firing rate recovery from the adaptive processes, the current was turned off for periods of < or = 10 s during the course of a 60-s trial.(ABSTRACT TRUNCATED AT 400 WORDS)
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“during ballistic contractions, motor units usually began to discharge at high instantaneous rates (60–120 Hz) that thereafter declined progressively during their successive discharges”
From Maximal discharge rate of motor units determines the maximal rate of force development during ballistic contractions in human (2014) · cites this paper as Sawczuk et al., 1995
Citations
Cites
Electric current flow in excitable cells
(1976) · American Heart Journal · doi:10.1016/s0002-8703(76)80560-1 · Cited by 1,289
Ionic Channels of Excitable Membranes, 2nd Ed.
Sullivan, H. (1992) · Neurology · doi:10.1212/wnl.42.7.1439-a · Cited by 1,270
Bigland-Ritchie, B., Dawson, N. J., Johansson, R. S., & Lippold, O. C. J. (1986) · The Journal of Physiology · doi:10.1113/jphysiol.1986.sp016263 · Cited by 613
Contractile speed and EMG changes during fatigue of sustained maximal voluntary contractions
Bigland-Ritchie, B., Johansson, R. S., Lippold, O. C. J., & Woods, J. J. (1983) · Journal of Neurophysiology · doi:10.1152/jn.1983.50.1.313 · Cited by 571
Aghajanian, G. K., & Rasmussen, K. (1989) · Synapse · doi:10.1002/syn.890030406 · Cited by 445
The effect of activation history on tension production by individual muscle units
Burke, R. E., Rudomin, P., & Zajac, F. E. (1976) · Brain Research · doi:10.1016/0006-8993(76)90031-7 · Cited by 406
Evidence for a fatigue-induced reflex inhibition of motoneuron firing rates
Woods, J. J., Furbush, F., & Bigland-Ritchie, B. (1987) · Journal of Neurophysiology · doi:10.1152/jn.1987.58.1.125 · Cited by 306
Properties of a persistent inward current in normal and TEA-injected motoneurons
Schwindt, P. C., & Crill, W. E. (1980) · Journal of Neurophysiology · doi:10.1152/jn.1980.43.6.1700 · Cited by 298
Quantitative aspects of repetitive firing of mammalian motoneurones, caused by injected currents
Granit, R., Kernell, D., & Shortess, G. K. (1963) · The Journal of Physiology · doi:10.1113/jphysiol.1963.sp007230 · Cited by 293
Schwindt, P. C., Spain, W. J., & Crill, W. E. (1989) · Journal of Neurophysiology · doi:10.1152/jn.1989.61.2.233 · Cited by 273
Cited by
Sorted by citations
Spinal and Supraspinal Factors in Human Muscle Fatigue
Gandevia, S. C. (2001) · Physiological Reviews · doi:10.1152/physrev.2001.81.4.1725 · Cited by 3,855
Synaptic Control of Motoneuronal Excitability
Rekling, J. C., Funk, G. D., Bayliss, D. A., Dong, X., & Feldman, J. L. (2000) · Physiological Reviews · doi:10.1152/physrev.2000.80.2.767 · Cited by 608
McIntyre, C. C., & Grill, W. M. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.88.4.1592 · Cited by 383
Vecchio, A. D., Negro, F., Holobar, A., Casolo, A., Folland, J. P., Felici, F., & Farina, D. (2019) · The Journal of Physiology · doi:10.1113/jp277396 · Cited by 349
Bistability in Spinal Motoneurons In Vivo: Systematic Variations in Persistent Inward Currents
Lee, R. H., & Heckman, C. J. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.80.2.583 · Cited by 347
Metadata
- Authors
- Sawczuk, A., Powers, R. K., & Binder, M. D.
- Affiliations
- University of Washington (US)
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 1995-05-01
- Volume
- 73
- Issue
- 5
- Pages
- 1799-1810
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2402388036
- Cited by
- 144
- References
- 45
- Citations by year
- 2026: 6 · 2025: 2 · 2024: 3 · 2023: 2 · 2022: 4 · 2021: 3 · 2020: 2 · 2019: 6 · 2018: 2 · 2017: 2 · 2016: 1 · 2015: 3 · 2014: 10 · 2013: 3 · 2012: 2
- FWCI
- 1.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Neurophysiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5k08ns001650-05)
- National Institute of Neurological Disorders and Stroke (NS-26840, R01NS026840, NS 01650)
- National Institute of Dental and Craniofacial Research (K16DE000161, DE 00161)
- Topics
- Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Neuroscience of respiration and sleep
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neuropharmacology Research
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ion channel regulation and function
- Keywords
- spike frequency adaptation, hypoglossal motoneurons, hypoglossal nucleus, repetitive firing, interspike intervals, input resistance, rheobase
- MeSH terms
- Animals, Brain Stem, Electrophysiology, Hypoglossal Nerve, Kinetics, Membrane Potentials, Motor Neurons, Neural Conduction, Time Factors, Rats, Sprague-Dawley, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review