Warm-Sensitive Afferent Splanchnic C-Fiber Units In Vitro
The DOI matches its Crossref record.
Abstract
Adelson, David W., Jen Yu Wei, and Lawrence Kruger. Warm-sensitive afferent splanchnic C-fiber units in vitro. J. Neurophysiol. 77: 2989–3002, 1997. Receptive fields of 41 slowly conducting sensory fibers were located using a thermal (warm) search stimulus in an in vitro splanchnic nerve-mesentery preparation. Warm-sensitive receptive fields were punctate and were densest in the region surrounding the prevertebral ganglia, an area with prominent deposits of brown adipose tissue, where the abdominal aorta branches into the major trunks supplying the abdominal viscera. Impulse activity was recorded while applying a warm stimulus to identified receptive fields (RFs). The warm stimulus consisted of a warming ramp (10–15°C in 1–2 s to a 42–49°C peak temperature) followed by a 10- to 30-s period during which the RF was maintained at this peak temperature (plateau phase). Eighty percent (33/41) of warm-sensitive units responded to warming with discharge comprising both a phasic and a tonic component (slowly adapting warm-sensitive, or SA-W, units). The remainder (8/41) responded with only phasic discharge (rapidly adapting warm-sensitive, or RA-W, units). Units' adaptation characteristics were consistent from trial to trial and when applying stimuli from different positions. Fifty percent of SA-W units (8/16) and 17% of RA-W units (1/6) were activated by transient exposure to 9–90 nM bradykinin (BK). Twenty-seven percent (9/33) of SA-W units and 12%(1/8) of RA-W units were activated by probing their RF with von Frey hairs with bending forces <10 mN (∼1 g equivalent mass). An additional five SA-W units tested were activated by strong mechanical stimuli (compression with a metal probe or firm stretching). No BK-responsive warm-sensitive units were activated by von Frey probing <10 mN, but two (both SA-W) responded to strong mechanical stimuli. In six SA-W units and one RA-W unit, the number of impulses evoked by warming ∼5 min after exposure to BK was >2 SD greater than the mean pre-BK response, indicating sensitization. This sensitization was transient, the response to warming returning to within one standard deviation of the pretrial mean or less over the course of the next 5–10 min. Changes in background activity, mechanical sensitivity, BK sensitivity, and BK-induced sensitization were noted in various splanchnic units over the course of prolonged observations, suggesting that these indices may not reliably distinguish unit type, but instead may indicate the functional state of the sense organ. Splanchnic neurons responsive to the intense warming used in the present in vitro experiments may participate in the cardiovascular responses observed in vivo in heat-stressed rats. The dense distribution of warm-receptive fields in the vicinity of the celiac-superior mesenteric ganglionic complex is consistent with the localization of splanchnic thermosensitive units previously noted in vivo in the rabbit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The central autonomic nervous system: conscious visceral perception and autonomic pattern generation
Saper, C. B. (2002) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.25.032502.111311 · Cited by 837
Neuroimaging of the brain–gut axis: From basic understanding to treatment of functional GI disorders
Mayer, E. A., Naliboff, B. D., & Craig, A. D. B. (2006) · Gastroenterology · doi:10.1053/j.gastro.2006.10.026 · Cited by 366
MERIGHI, A., SALIO, C., GHIRRI, A., LOSSI, L., FERRINI, F., BETELLI, C., & BARDONI, R. (2008) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2008.04.004 · Cited by 354
Lever, I. J., Bradbury, E. J., Cunningham, J. R., Adelson, D. W., Jones, M. G., McMahon, S. B., Marvizón, J. C. G., & Malcangio, M. (2001) · The Journal of Neuroscience · doi:10.1523/jneurosci.21-12-04469.2001 · Cited by 300
Self-citationThe transient receptor potential vanilloid-1 channel in thermoregulation: a thermosensor it is not
Romanovsky, A. A., Almeida, M. C., Garami, A., Steiner, A. A., Norman, M. H., Morrison, S. F., Nakamura, K., Burmeister, J. J., & Nucci, T. B. (2009) · Pharmacological Reviews · doi:10.1124/pr.109.001263 · Cited by 253
“Nevertheless, warmth-sensitive units certainly exist in the core and are relatively abundant in some organs (e.g., the mesentery) (Adelson et al., 1997).”
BackgroundBDNF: a neuromodulator in nociceptive pathways?
Pezet, S., Malcangio, M., & McMahon, S. B. (2002) · Brain Research Reviews · doi:10.1016/s0165-0173(02)00206-0 · Cited by 218
“Given the fact that SP and BDNF are likely to be or capsaicin, is underscored by observations that C-fibres present in the same population of primary afferents [45], can adopt a bursting firing pattern when the intensity of and they may be co-packaged in large, dense-core synaptic nociceptive stimuli increases over a…”
BackgroundCharacterization of mechanosensitive splanchnic nerve afferent fibers innervating the rat stomach
Ozaki, N., & Gebhart, G. F. (2001) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.2001.281.6.g1449 · Cited by 100
“(1, 2), employing an in vitro preparation of rat mesenteric nerve, reported H2O2- and bradykinin-sensitive splanchnic afferent C-fiber units.”
Background
Metadata
- Authors
- Adelson, D. W., Wei, J. Y., & Kruger, L.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 1997-06-01
- Volume
- 77
- Issue
- 6
- Pages
- 2989-3002
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2296013521
- Cited by
- 36
- References
- 0
- FWCI
- 1.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.