Passive Electrical Properties of Ventral Horn Neurons in Rat Spinal Cord Slices
Open accessThe DOI matches its Crossref record.
Abstract
Thurbon, David, Hans-R. Lüscher, Thomas Hofstetter, and Stephen J. Redman. Passive electrical properties of ventral horn neurons in rat spinal cord slices. J. Neurophysiol. 79: 2485–2502, 1998. Recordings were made from large neurons located in the ventral horn of transverse spinal cord slices from young rats (7–15 days). Whole cell recordings were made simultaneously with two electrodes from the soma of these neurons, visualized using infra-red differential interference contrast optics. Positive identification of motoneurons could not always be achieved. The response of a neuron to a brief pulse of current delivered by one electrode, and recorded by the other electrode, were matched optimally to responses of a compartmental model of the same neuron with an identical current pulse as input. The compartmental model was based on a reconstruction of the neuron, using Biocytin staining. The compartmental model had three free parameters: specific membrane capacitance ( C m), membrane resistivity ( R m), and cytoplasmatic resistivity ( R i), all assumed to be uniform throughout the neuron. The experimental and model responses could be matched unequivocally for four neurons, giving C m = 2.4 ± 0.5 μF/cm 2, R m = 5.3 ± 0.9 kΩ/cm 2, and R i = 87 ± 22 Ω/cm. No somatic shunt was required. For the remaining six neurons, a less perfect fit (but still within 95% confidence limits) was indicative of nonhomogeneous membrane properties. The electrotonic length of uncut dendrites was 0.85 ± 0.14 λ. The results resolve the issue of a somatic shunt conductance for motoneurons, relegating it to a microelectrode impalement artifact. They are consistent with previous reports on the electrical compactness of motoneurons to steady state currents and voltages. However, the much higher value of C m (than the previously assumed 1 μF/cm 2) implies much greater dendritic attenuation of fast synaptic potentials, and a much enhanced integrative response of motoneurons to synaptic potentials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Neuron: A Tool for Neuroscientists
Hines, M. L., & Carnevale, N. T. (2001) · The Neuroscientist · doi:10.1177/107385840100700207 · Cited by 634
Synaptic Control of Motoneuronal Excitability
Rekling, J. C., Funk, G. D., Bayliss, D. A., Dong, X.-W., & Feldman, J. L. (2000) · Physiological Reviews · doi:10.1152/physrev.2000.80.2.767 · Cited by 607
Determinants of Voltage Attenuation in Neocortical Pyramidal Neuron Dendrites
Stuart, G., & Spruston, N. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-10-03501.1998 · Cited by 524
Direct Measurement of Specific Membrane Capacitance in Neurons
Gentet, L. J., Stuart, G. J., & Clements, J. D. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76293-x · Cited by 452
Feldmeyer, D., Egger, V., Lübke, J., & Sakmann, B. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.00169.x · Cited by 441
Excitation of Central Nervous System Neurons by Nonuniform Electric Fields
McIntyre, C. C., & Grill, W. M. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77251-6 · Cited by 319
Roth, A., & Häusser, M. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.00445.x · Cited by 278
Input-output functions of mammalian motoneurons
Powers, R. K., & Binder, M. D. (2007) · Reviews of Physiology, Biochemistry and Pharmacology · doi:10.1007/bfb0115594 · Cited by 276
Selective Microstimulation of Central Nervous System Neurons
McIntyre, C. C., & Grill, W. M. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.262 · Cited by 258
Dendritic L‐type calcium currents in mouse spinal motoneurons: implications for bistability
Carlin, K. P., Jones, K. E., Jiang, Z., Jordan, L. M., & Brownstone, R. M. (2000) · European Journal of Neuroscience · doi:10.1046/j.1460-9568.2000.00055.x · Cited by 236
Unique membrane properties and enhanced signal processing in human neocortical neurons
Eyal, G., Verhoog, M. B., Testa-Silva, G., Deitcher, Y., Lodder, J. C., Benavides-Piccione, R., Morales, J., DeFelipe, J., de Kock, C. P., Mansvelder, H. D., et al. (2016) · eLife · doi:10.7554/elife.16553 · Cited by 196
“It is important to note that a few studies have demonstrated that Cm in rodent’s pyramidal neurons may range between 0.7–2 mF/cm 2 (Major et al., 1994; Thurbon et al., 1998), but direct measurements using nucleated patches found a much narrower range, 0.8–1.1 mF/cm2, in cortical pyramidal neurons…”
BackgroundInfluentialNeuromodulation: present and emerging methods
Luan, S., Williams, I., Nikolic, K., & Constandinou, T. G. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00027 · Cited by 162
“Clinically this approach is used in cochlear implants and is the most popular method in research publications (Thurbon et al., 1998; Srinivasan et al., 2010).”
MethodTahayori, B., Meffin, H., Sergeev, E. N., Mareels, I. M. Y., Burkitt, A. N., & Grayden, D. B. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/6/065005 · Cited by 24
Metadata
- Authors
- Thurbon, D., Lüscher, H.-R., Hofstetter, T., & Redman, S. J.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 1998-05-01
- Volume
- 79
- Issue
- 5
- Pages
- 2485-2502
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W1832017581
- Cited by
- 101
- References
- 0
- FWCI
- 2.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.