CoChat

Pattern of Pulses That Maximize Force Output From Single Human Thenar Motor Units

Thomas, C. K., Johansson, R. S., Bigland-Ritchie, B. · 1999 · Journal of Neurophysiology
Cited by 61

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

We assessed the sequence of nerve impulses that maximize force output from individual human thenar motor units. When these motor units were stimulated intraneurally by a variable sequence of seven pulses, the pattern of pulses that elicited maximum force always started with a short (5–15 ms) interpulse interval termed a “doublet.” The twitch force summation caused by this “doublet” elicited, on average, 48 ± 13% (SD) of the maximum tetanic force. The peak amplitude of “doublet” forces was 3.5 times that of the initial twitches, and twitch potentiation appeared to have little influence on twitch force summation elicited by the “doublets.” For some units, the second optimal interpulse interval was also short. Peak forces elicited by the third to sixth interpulse intervals did not change substantially when the last interpulse interval was varied between 5 to 55 ms, so maximum force could not be attributed to any unique interpulse interval. Each successive pulse contributed a smaller force increment. When five to seven pulses were delivered in an optimal sequence, the evoked force was close to that recorded during maximal tetanic stimulation. In contrast, maximal force-time integral was evoked with one short interpulse interval (5–15 ms) then substantially longer interpulse intervals (>100 ms). Maximum force and force-time integrals were therefore elicited by different patterns of stimuli. We conclude that a brief initial interpulse interval (5–15 ms) is required to elicit maximum “doublet” force from human thenar motor units and that near-maximal tetanic forces can be elicited by only five or six additional post-“doublet” pulses if appropriately spaced in time. However, the rate at which these post-“doublet” stimuli must be provided is fairly uncritical. In contrast, maximum post-“doublet” force-time integrals were obtained at intervals corresponding to motoneuronal firing rates of ∼7 Hz, rates close to that typically used to recruit motor units and to maintain weak voluntary contractions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1999.82.6.3188

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 61

Metadata

Authors
Thomas, C. K., Johansson, R. S., & Bigland-Ritchie, B.
Venue
Journal of Neurophysiology
Published
1999-12-01
Volume
82
Issue
6
Pages
3188-3195
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2463260843
Cited by
61
References
4
FWCI
4.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pattern of Pulses That Maximize Force Output From Single Human Thenar Motor Units. https://app.cochat.ai/papers/10.1152/jn.1999.82.6.3188
The paper
Thomas, C. K., Johansson, R. S., & Bigland-Ritchie, B. (1999). Pattern of Pulses That Maximize Force Output From Single Human Thenar Motor Units. Journal of Neurophysiology. https://doi.org/10.1152/jn.1999.82.6.3188

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.