CoChat

Effects of Common Excitatory and Inhibitory Inputs on Motoneuron Synchronization

Türker, K. S., Powers, R. K. · 2001 · Journal of Neurophysiology
Cited by 46

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

We compared the effects of common excitatory and inhibitory inputs on motoneuron synchronization by simulating synaptic inputs with injected current transients. We elicited repetitive discharge in hypoglossal motoneurons recorded in slices of rat brain stem using a combination of a suprathreshold injected current step with superimposed noise to mimic the synaptic drive likely to occur during physiological activation. The effects of common inputs to motoneurons were simulated by the addition of a waveform composed of from 6 to 300 trains of current transients designed to mimic excitatory and/or inhibitory synaptic currents. We compared the discharge records obtained in several trials in which the same “common input” waveform was applied repeatedly in the presence of different background noise waveforms. The effects of the common input on motoneuron discharge probability and discharge rate were determined by compiling a cross-correlation histogram (CCHist) and a perispike frequencygram (PSFreq) between the discharges of the same cell at different times. Both excitatory and inhibitory common inputs induced synchronous discharge that was evident by a large central peak in the CCHist. The CCHists produced by common excitatory inputs were characterized by larger and narrower central peaks than those generated by common inhibitory inputs. The PSFreqs produced by common excitatory inputs indicated an increase in the discharge rate of motoneurons around time 0 that coincided with the narrow and large central peak in the CCHist. On the other hand, inhibitory inputs often generated very little, if any, change in the discharge rate around time 0 corresponding with the small and wide central peak in the CCHist. These results suggest that the CCHist indicates the effective strength of the net common input but not its sign. Although correlated changes in discharge rate are often quite different for net excitatory and inhibitory common input, except in some restricted conditions, the PSFreq analysis also cannot be used to unambiguously distinguish net excitation from net inhibition.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.2001.86.6.2807

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 46

Metadata

Authors
Türker, K. S., & Powers, R. K.
Venue
Journal of Neurophysiology
Published
2001-12-01
Volume
86
Issue
6
Pages
2807-2822
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W1876391208
Cited by
46
References
3
FWCI
1.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.