Fluid Transport Across Leaky Epithelia: Central Role of the Tight Junction and Supporting Role of Aquaporins
Open accessThe DOI matches its Crossref record.
Abstract
The mechanism of epithelial fluid transport remains unsolved, which is partly due to inherent experimental difficulties. However, a preparation with which our laboratory works, the corneal endothelium, is a simple leaky secretory epithelium in which we have made some experimental and theoretical headway. As we have reported, transendothelial fluid movements can be generated by electrical currents as long as there is tight junction integrity. The direction of the fluid movement can be reversed by current reversal or by changing junctional electrical charges by polylysine. Residual endothelial fluid transport persists even when no anions (hence no salt) are being transported by the tissue and is only eliminated when all local recirculating electrical currents are. Aquaporin (AQP) 1 is the only AQP present in these cells, and its deletion in AQP1 null mice significantly affects cell osmotic permeability (by ∼40%) but fluid transport much less (∼20%), which militates against the presence of sizable water movements across the cell. In contrast, AQP1 null mice cells have reduced regulatory volume decrease (only 60% of control), which suggests a possible involvement of AQP1 in either the function or the expression of volume-sensitive membrane channels/transporters. A mathematical model of corneal endothelium we have developed correctly predicts experimental results only when paracellular electro-osmosis is assumed rather than transcellular local osmosis. Our evidence therefore suggests that the fluid is transported across this layer via the paracellular route by a mechanism that we attribute to electro-osmotic coupling at the junctions. From our findings we have developed a novel paradigm for this preparation that includes 1) paracellular fluid flow; 2) a crucial role for the junctions; 3) hypotonicity of the primary secretion; and 4) an AQP role in regulation rather than as a significant water pathway. These elements are remarkably similar to those proposed by the laboratory of Adrian Hill for fluid transport across other leaky epithelia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cerebrospinal fluid secretion by the choroid plexus
Damkier, H. H., Brown, P. D., & Praetorius, J. (2013) · Physiological Reviews · doi:10.1152/physrev.00004.2013 · Cited by 606
“In the electrodiffusion model (FIGURE 6B), Fischbarg (96) basically agreed with Hill’s model with a few prominent differences.”
MethodRole of CFTR in epithelial physiology
Saint-Criq, V., & Gray, M. A. (2017) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-016-2391-y · Cited by 433
“For both processes, water moves either passively through the paracellular pathway or transcellularly via aquaporins, or by both routes [9–11] (Fig.”
BackgroundMolecular mechanisms underlying the corneal endothelial pump
Bonanno, J. A. (2012) · Experimental Eye Research · doi:10.1016/j.exer.2011.06.004 · Cited by 408
Hanukoglu, I., & Hanukoglu, A. (2016) · Gene · doi:10.1016/j.gene.2015.12.061 · Cited by 390
Cerebrospinal fluid dynamics and intracranial pressure elevation in neurological diseases
Bothwell, S. W., Janigro, D., & Patabendige, A. (2019) · Fluids and Barriers of the CNS · doi:10.1186/s12987-019-0129-6 · Cited by 319
Comparative Digestive Physiology
H. Karasov, W., & Douglas, A. E. (2013) · Comprehensive Physiology · doi:10.1002/cphy.c110054 · Cited by 308
Human aquaporins: Regulators of transcellular water flow
Day, R. E., Kitchen, P., Owen, D. S., Bland, C., Marshall, L., Conner, A. C., Bill, R. M., & Conner, M. T. (2014) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2013.09.033 · Cited by 305
Osmoregulation and epithelial water transport: lessons from the intestine of marine teleost fish
Whittamore, J. M. (2012) · Journal of Comparative Physiology B · doi:10.1007/s00360-011-0601-3 · Cited by 183
Water channel proteins in the gastrointestinal tract
Laforenza, U. (2012) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2012.03.001 · Cited by 174
Intestinal fluid absorption in anadromous salmonids: importance of tight junctions and aquaporins
Sundell, K. S., & Sundh, H. (2012) · Frontiers in Physiology · doi:10.3389/fphys.2012.00388 · Cited by 135
“, the driving force behind the fluid transport across the intestine is thoroughly investigated, the main route for water flow, is under debate and has not yet been established (Alves et al., 1999; Hill et al., 2004; Fischbarg, 2010; Laforenza, 2012).”
Background
Metadata
- Authors
- Fischbarg, J.
- Venue
- Physiological Reviews
- Publisher
- American Physiological Society
- Published
- 2010-10
- Volume
- 90
- Issue
- 4
- Pages
- 1271-1290
- ISSN
- 0031-9333 (ISSN-L)
- 1522-1210
- OpenAlex
- W2135607892
- Cited by
- 128
- References
- 0
- FWCI
- 0.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.