Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 166

The DOI matches its Crossref record.

Electrical Dimension of the Nuclear Envelope

Mazzanti, Michele, Bustamante, José Omar, Oberleithner, Hans·2001·Physiological Reviews

Abstract

Eukaryotic chromosomes are confined to the nucleus, which is separated from the rest of the cell by two concentric membranes known as the nuclear envelope (NE). The NE is punctuated by holes known as nuclear pore complexes (NPCs), which provide the main pathway for transport of cellular material across the nuclear-cytoplasmic boundary. The single NPC is a complicated octameric structure containing more than 100 proteins called nucleoporins. NPCs function as transport machineries for inorganic ions and macromolecules. The most prominent feature of an individual NPC is a large central channel, ∼7 nm in width and 50 nm in length. NPCs exhibit high morphological and functional plasticity, adjusting shape to function. Macromolecules ranging from 1 to >100 kDa travel through the central channel into (and out of) the nucleoplasm. Inorganic ions have additional pathways for communication between cytosol and nucleus. NE can turn from a simple sieve that separates two compartments by a given pore size to a smart barrier that adjusts its permeabiltiy to the metabolic demands of the cell. Early microelectrode work characterizes the NE as a membrane barrier of highly variable permeability, indicating that NPCs are under regulatory control. Electrical voltage across the NE is explained as the result of electrical charge separation due to selective barrier permeability and unequal distribution of charged macromolecules across the NE. Patch-clamp work discovers NE ion channel activity associated with NPC function. From comparison of early microelectrode work with patch-clamp data and late results obtained by the nuclear hourglass technique, it is concluded that NPCs are well-controlled supramolecular structures that mediate transport of macromolecules and small ions by separate physical pathways, the large central channel and the small peripheral channels, respectively. Electrical properties of the two pathways are still unclear but could have great impact on the understanding of signal transfer across NE and gene expression.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/physrev.2001.81.1.1

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 166

Metadata

Authors
Mazzanti, M., Bustamante, J. O., & Oberleithner, H.
Venue
Physiological Reviews
Published
2001-01-01
Volume
81
Issue
1
Pages
1-19
ISSN
  • 0031-9333 (ISSN-L)
  • 1522-1210
OpenAlex
W2277231187
Cited by
166
References
0
FWCI
0.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrical Dimension of the Nuclear Envelope. https://app.cochat.ai/papers/10.1152/physrev.2001.81.1.1
The paper
Mazzanti, M., Bustamante, J. O., & Oberleithner, H. (2001). Electrical Dimension of the Nuclear Envelope. Physiological Reviews. https://doi.org/10.1152/physrev.2001.81.1.1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.