The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electrophysiology of the Sodium-Potassium-ATPase in Cardiac Cells
Abstract
Like several other ion transporters, the Na+-K+pump of animal cells is electrogenic. The pump generates the pump current I p. Under physiological conditions, I p is an outward current. It can be measured by electrophysiological methods. These methods permit the study of characteristics of the Na+-K+pump in its physiological environment, i.e., in the cell membrane. The cell membrane, across which a potential gradient exists, separates the cytosol and extracellular medium, which have distinctly different ionic compositions. The introduction of the patch-clamp techniques and the enzymatic isolation of cells have facilitated the investigation of I p in single cardiac myocytes. This review summarizes and discusses the results obtained from I p measurements in isolated cardiac cells. These results offer new exciting insights into the voltage and ionic dependence of the Na+-K+pump activity, its effect on membrane potential, and its modulation by hormones, transmitters, and drugs. They are fundamental for our current understanding of Na+-K+pumping in electrically excitable cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hamill, O. P., Marty, A., Neher, E., Sakmann, B., & Sigworth, F. J. (1981) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00656997 · Cited by 18,436
Cited by
Na+-K+Pump Regulation and Skeletal Muscle Contractility
CLAUSEN, T. (2003) · Physiological Reviews · doi:10.1152/physrev.00011.2003 · Cited by 583
Intracellular Na+ regulation in cardiac myocytes
Bers, D. (2003) · Cardiovascular Research · doi:10.1016/s0008-6363(02)00656-9 · Cited by 306
Astrocytes Modulate Neural Network Activity by Ca 2+ -Dependent Uptake of Extracellular K +
Wang, F., Smith, N. A., Xu, Q., Fujita, T., Baba, A., Matsuda, T., Takano, T., Bekar, L., & Nedergaard, M. (2012) · Science Signaling · doi:10.1126/scisignal.2002334 · Cited by 291
Phospholemman (FXYD1) associates with Na,K-ATPase and regulates its transport properties
Crambert, G., Füzesi, M., Garty, H., Karlish, S., & Geering, K. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.182267299 · Cited by 272
The Na(+)/K(+) pump dominates control of glycolysis in hippocampal dentate granule cells
Meyer, D. J., Díaz-García, C. M., Nathwani, N., Rahman, M., & Yellen, G. (2022) · eLife · doi:10.7554/elife.81645 · Cited by 40
Metadata
- Authors
- Glitsch, H. G.
- Venue
- Physiological Reviews
- Publisher
- American Physiological Society
- Published
- 2001-01-10
- Volume
- 81
- Issue
- 4
- Pages
- 1791-1826
- ISSN
- 0031-9333 (ISSN-L)
- 1522-1210
- OpenAlex
- W2109193104
- Cited by
- 224
- References
- 1
- FWCI
- 0.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrophysiology of the Sodium-Potassium-ATPase in Cardiac Cells. https://app.cochat.ai/papers/10.1152/physrev.2001.81.4.1791
- The paper
- Glitsch, H. G. (2001). Electrophysiology of the Sodium-Potassium-ATPase in Cardiac Cells. Physiological Reviews. https://doi.org/10.1152/physrev.2001.81.4.1791
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.