The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Carbon Nanotube‐Based Electrochemical Sensors: Principles and Applications in Biomedical Systems
Open accessAbstract
Carbon nanotubes (CNTs) have received considerable attention in the field of electrochemical sensing, due to their unique structural, electronic and chemical properties, for instance, unique tubular nanostructure, large specific surface, excellent conductivity, modifiable sidewall, high conductivity, good biocompatibility, and so on. Here, we tried to give a comprehensive review on some important aspects of the applications of CNT‐based electrochemical sensors in biomedical systems, including the electrochemical nature of CNTs, the methods for dispersing CNTs in solution, the approaches to the immobilization of functional CNT sensing films on electrodes, and the extensive biomedical applications of the CNT‐based electrochemical sensors. In the last section, we mainly focused on the applications of CNT‐based electrochemical sensors in the analysis of various biological substances and drugs, the methods for constructing enzyme‐based electrochemical biosensors and the direct electron transfer of redox proteins on CNTs. Because several crucial factors (e.g., the surface properties of carbon nanotubes, the methods for constructing carbon nanotube electrodes and the manners for electrochemical sensing applications) predominated the analytical performances of carbon nanotube electrodes, a systematical comprehension of the related knowledge was essential to the acquaintance, mastery and development of carbon nanotube‐based electrochemical sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noncovalent sidewall functionalization of single-walled carbon nanotubes for protein immobilization
Chen, R. J., Zhang, Y., Wang, D., & Dai, H. (2001) · Journal of the American Chemical Society · doi:10.1021/ja010172b · Cited by 2,534
Cited by
Immobilization strategies to develop enzymatic biosensors
Sassolas, A., Blum, L. J., & Leca-Bouvier, B. D. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.09.003 · Cited by 1,130
Peng, Z., Liu, X., Zhang, W., Zeng, Z., Liu, Z., Zhang, C., Liu, Y., Shao, B., Liang, Q., Tang, W., et al. (2020) · Environment International · doi:10.1016/j.envint.2019.105298 · Cited by 412
Xu, J., Wang, Y., & Hu, S. (2017) · Microchimica Acta · doi:10.1007/s00604-016-2007-0 · Cited by 405
Self-citationAlshehri, R., Ilyas, A. M., Hasan, A., Arnaout, A., Ahmed, F., & Memic, A. (2016) · Journal of Medicinal Chemistry · doi:10.1021/acs.jmedchem.5b01770 · Cited by 381
Non-Covalent Functionalization of Carbon Nanotubes for Electrochemical Biosensor Development
Zhou, Y., Fang, Y., & Ramasamy, R. (2019) · Sensors · doi:10.3390/s19020392 · Cited by 347
Metadata
- Authors
- Hu, C., & Hu, S.
- Venue
- Journal of Sensors
- Publisher
- Wiley
- Published
- 2009-01
- Volume
- 2009
- Issue
- 1
- ISSN
- 1687-725X (ISSN-L)
- 1687-7268
- OpenAlex
- W2014857246
- Cited by
- 176
- References
- 1
- FWCI
- 8.98
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Carbon Nanotube‐Based Electrochemical Sensors: Principles and Applications in Biomedical Systems. https://app.cochat.ai/papers/10.1155/2009/187615
- The paper
- Hu, C., & Hu, S. (2009). Carbon Nanotube‐Based Electrochemical Sensors: Principles and Applications in Biomedical Systems. Journal of Sensors. https://doi.org/10.1155/2009/187615
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.